Interferometric analysis of diffractive multifocal intraocular lenses.
Seung Pil Bang, Gi Hoon Lim, Seth Pantanelli
From the Department of Ophthalmology, Keimyung University School of Medicine, Daegu, South Korea (Bang, Lim); Department of Ophthalmology, Penn State College of Medicine, Hershey, Pennsylvania (Pantanelli).
Key points
From the paper's conclusion- Interferometric optical metrology revealed distinct through-focus optical profiles among contemporary diffractive multifocal IOLs, reflecting design-dependent differences in focal energy distribution across pupil sizes.
Abstract
PURPOSE: To characterize the surface metrology of 4 multifocal intraocular lenses (IOLs) and simulate their behavior across pupil sizes. SETTING: Physiological Optics & Imaging Laboratory, Daegu, South Korea. DESIGN: Laboratory investigation. METHODS: Four +20.0-diopter multifocal IOLs-Envy, PanOptix, Odyssey, and Synergy-were evaluated using a Mach-Zehnder interferometer (NIMO TEMPO) following ISO 11979-2 standards. Optical path difference maps generated wavefront profiles, diffractive step profiles, point spread functions, and modulation transfer functions (MTFs). Through-focus MTFs were obtained at 50 line pairs per millimeter under of 2.0 mm, 3.0 mm, and 4.5 mm pupil diameters. RESULTS: Envy exhibited gradually decreasing diffractive step heights peripherally, favoring distance vision under mesopic conditions. PanOptix maintained uniform step heights, whereas Odyssey and Synergy exhibited larger diffractive steps with significant primary and secondary spherical aberrations, producing extended depth-of-field. Odyssey exhibited a distance-dominant energy distribution, while Synergy displayed a more balanced intermediate and near dispersal. Through-focus MTFs revealed stable trifocal peaks for Envy, a near-shifted tendency for PanOptix under small pupils, and far-dominant patterns for Odyssey and Synergy converging under larger pupils. CONCLUSIONS: Interferometric optical metrology revealed distinct through-focus optical profiles among contemporary diffractive multifocal IOLs, reflecting design-dependent differences in focal energy distribution across pupil sizes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Earlier to Updated Quadrifocal Intraocular Lens Designs: An Objective Optical Metrology Analysis.Journal of cataract and refractive surgery · 2026
- Comparative Optical Performance of Two Enhanced Monofocal IOLs Across Pupil Sizes and Lens Powers.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- In Vitro Optical Bench Assessment of an Extended Depth-of-Focus Intraocular Lens Based on Segmented Refractive Design.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Quantification of Peripheral Blur in Ultra-Widefield Fundus Imaging Following Diffractive Multifocal Intraocular Lens Implantation.Journal of clinical medicine · 2026
- Fabrication and in vitro optical characterization of a diffractive trifocal intraocular lens with step heights modulated by a cosine function.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Visual Performance of a Novel Intraocular Lens With Higher-Order Aspheric Design Optimized for Intermediate Vision.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026