Journal of Cataract & Refractive SurgeryPupil size

Impact of pupil size on defocus curve, contrast sensitivity and patient satisfaction in a diffractive, simultaneous vision intraocular lens

Petra Dávidová, Klemens Paul Kaiser, Tyll Jandewerth, Eva Hemkeppler, Myriam Böhm, Tom Struller, Thomas Kohnen

Goethe University Frankfurt · St. Marien Hospital

Key points

From the paper's conclusion
  • To evaluate the relationship between pupil size (PS) and defocus curve, contrast sensitivity (CS), spectacle independence and patient satisfaction after implantation of a diffractive, simultaneous vision intraocular lens (SVL; AcrySof® IQ PanOptix®, Alcon).

Abstract

PURPOSE: To evaluate the relationship between pupil size (PS) and defocus curve, contrast sensitivity (CS), spectacle independence and patient satisfaction after implantation of a diffractive, simultaneous vision intraocular lens (SVL; AcrySof® IQ PanOptix®, Alcon). SETTING: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. DESIGN: Post-hoc analysis of prospective studies. METHODS: Patients were included three months after bilateral implantation of a diffractive SVL. Exclusion criteria included any ocular pathologies or previous ocular surgeries besides cataract or refractive lens exchange. Monocular defocus curve and infrared-based-pupillometry (PupilX, Albomed) in mesopic (MC) and photopic conditions (PC) and binocular visual acuity (VA) in various distances, CS, satisfaction in daily activities (driving day/night, TV, theater, home, PC, newspaper, cooking, domestic work) and spectacle independence for distance, intermediate and near were obtained. PS was analyzed continuously and categorized in small (≤4mm (MC); ≤2.5mm (PC)), medium (>4 - 5mm (MC); >2.5 - 4 mm (PC)) and large (>5mm (MC); >4 mm (PC)). RESULTS: Fifty-two patients (mean age 68 years) were included. Three months postoperatively PS was 4.24 (2.60-6.10) mm in MC and 3.38 (1.20-5.60) mm in PC. Besides correlations with extreme ends of the defocus curve, especially photopic PS weakly correlated with near-visual and partially with the intermediate range. Smaller photopic PS led partially to more near-spectacle independence. Photopic and mesopic PS moderately correlated with RoF ≤0.2 and 0.3 logMAR. Smaller pupils yielded better VA across the defocus curve, bigger RoF and a trend of being more satisfied with newspaper reading. In the other parameters, PS was not significant. CONCLUSIONS: PS especially affected the near-visual range, near-spectacle independence and RoF in a diffractive, SVL.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Impact of pupil size on defocus curve, contrast sensitivity and patient satisfaction in a diffractive, simultaneous vision intraocular lens — Science Skim