Visual Performance of Two Daily Disposable Multifocal Contact Lenses in Presbyopic Soft Lens Wearers.
Ulrike Stahl, Jill Woods, Alison Ng, Doerte Luensmann, Lyndon Jones
Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada.
Key points
From the paper's conclusion- Both lenses provided good vision across a variety of distances at high and low illumination. DT1 MF was non-inferior to AOM MF in HCVA under photopic and mesopic illumination at distance, intermediate and near. HCVA at all distances with both study lenses was independent of pupil size. Despite their different design, both study lenses performed equally well and provide a suitable vision correction for presbyopic CL wearers, irrespective of pupil size.
Abstract
PURPOSE: To measure high contrast visual acuity (HCVA) when presbyopic soft contact lens (CL) wearers, requiring a spectacle addition from +0.75 to +1.75 dioptres were fit bilaterally with delefilcon A daily disposable multifocal (DT1 MF) CLs and senofilcon A daily disposable multifocal (AOM MF) CLs. METHODS: In this prospective, randomized, double-masked, cross-over, non-inferiority study, presbyopic CL wearers wore two types of multifocal CLs for 1 hour each. HCVA was measured monocularly and binocularly at 6m, 66cm and 40cm under photopic and mesopic conditions. Participants rated subjective visual clarity (0-100 scale, 100=very clear) after each HCVA assessment. Pupil size was assessed under photopic and mesopic conditions. RESULTS: Twenty-eight participants (48.6 ± 5.3 years) completed the study. DT1 MF was non-inferior to AOM MF in HCVA at 6m, 66cm and 40cm in photopic and mesopic conditions for the dominant and non-dominant eye, and binocularly. There were no statistically significant differences between lenses for subjective visual clarity ratings for any of the viewing distances, whether evaluated for photopic or mesopic conditions for the dominant or non-dominant eye or binocularly. Mean pupil size in the dominant eye was 3.6 ± 0.5mm (2.6 to 4.5mm) and 5.1 ± 0.8mm (2.8 to 6.1mm) in photopic and mesopic conditions respectively. HCVA under photopic or mesopic illumination at 6m, 66cm or 40cm was not associated with pupil size (Pearson correlation, all p>0.05). CONCLUSION: Both lenses provided good vision across a variety of distances at high and low illumination. DT1 MF was non-inferior to AOM MF in HCVA under photopic and mesopic illumination at distance, intermediate and near. HCVA at all distances with both study lenses was independent of pupil size. Despite their different design, both study lenses performed equally well and provide a suitable vision correction for presbyopic CL wearers, irrespective of pupil size.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Refractive status and visual function in patients with pre-presbyopia and presbyopia wearing monofocal soft contact lenses without glasses in daily life.Japanese journal of ophthalmology · 2026
- Digital Visual Acuity and Reading Performance with Positive and Negative Display Polarities After Bilateral Diffractive Multifocal Intraocular Lens Implantation: A Longitudinal Observational Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Impact of pupil size on defocus curve, contrast sensitivity and patient satisfaction in a diffractive, simultaneous vision intraocular lensJournal of Cataract & Refractive Surgery · 2026
- Short-term visual and ocular responses to a myopia control contact lens: influence of optical zones and hydration techniques.Contact lens & anterior eye : the journal of the British Contact Lens Association · 2026
- Pupil Size Associations and Refractive Error Tolerance in Enhanced Monofocal Intraocular Lenses With Different Central Optic Designs.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Multifocal toric contact lenses improve low-contrast reading performance in presbyopes with moderate astigmatism.Contact lens & anterior eye : the journal of the British Contact Lens Association · 2026