Comparison of Compass and Humphrey Perimetry: Test-Retest Variability at Glaucomatous Scotoma edges.
Juleke E A Majoor, Koenraad A Vermeer, Hans G Lemij
Rotterdam Ophthalmic Institute, The Rotterdam Eye Hospital, P.O. Box 70030, 3000 LM Rotterdam, The Netherlands. · Novo Research Consultancy, Voorburg, The Netherlands.
Key points
From the paper's conclusion- CMP and HFA show comparable variability at scotoma borders with 24-2 VF testing, indicating no significant advantage of CMP eye tracking in reducing scotoma edge variability.
Abstract
PRCIS: The Compass perimeter, despite its integrated eye-tracking, demonstrated similar variability at scotoma borders with 24-2 visual field testing in glaucoma patients compared to the conventional Humphrey Field Analyzer. PURPOSE: Increased variability at the borders of glaucomatous scotomas measured with the Humphrey Field Analyzer (HFA) has been partly attributed to gaze instability. The Compass perimeter (CMP), which incorporates eye tracking to compensate for gaze instability, may reduce variability at scotoma borders. This study determined the test-retest variability (TRV) at scotoma borders measured with the CMP and compared it with that of the HFA. METHODS: One eye of each glaucoma patient was tested with both the CMP (24-2 ZEST) and the HFA (24-2 SITA standard) during three visits (screening, baseline, and follow-up). Eyes were stratified by mean deviation (MD) into mild (MD >-6 dB), moderate (-12 dB ≤MD <-6 dB) or advanced glaucoma (MD <-12 dB). Scotoma borders were identified using the HFA total deviation plot from the screening visit. TRV at scotoma edges was defined as the mean absolute difference of scotoma border points (SBP) between baseline and follow-up visual field (VF) tests (3-10 d apart). TRV was compared between devices using the Wilcoxon signed-rank test. RESULTS: 29 eyes (31% women; median [IQR] age 64 [56-72] years) were included. Mean (SD) time between baseline and follow-up was 6.4 (1.3) days. No statistically significant differences in SBP-TRV were found between CMP and HFA for all glaucoma stages combined (1.8 vs. 1.9 dB, P=0.42) or within individual stages. CONCLUSION: CMP and HFA show comparable variability at scotoma borders with 24-2 VF testing, indicating no significant advantage of CMP eye tracking in reducing scotoma edge variability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of the Perimouse Online Suprathreshold Visual Field Test for Glaucoma Screening in a Chinese Population: A Comparison with the Humphrey Field Analyzer.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Assessing Visual Field Defects in Glaucoma Using the Perceptive Scotoma Finder.Korean journal of ophthalmology : KJO · 2026
- Complementary Visual Assessment: Validation of a High-Precision Eye-Tracking Kinetic Perimetry in the Evaluation of Visual Field Deficits in Hemianopia.Restorative neurology and neuroscience · 2026
- Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma.Diagnostics (Basel, Switzerland) · 2026
- Feasibility and performance of eye movement perimetry for glaucoma triage in Tanzania: A prospective cross-sectional study in a real-world setting.PLOS global public health · 2026
- Performance of 24-2C Visual Field Grid in Detecting Central Glaucomatous Defects: A Comparative Study with Microperimetry.Journal of glaucoma · 2026