Feasibility and performance of eye movement perimetry for glaucoma triage in Tanzania: A prospective cross-sectional study in a real-world setting.
Arun J Thirunavukarasu, Victor H Hu, Pete R Jones, Elliott H Taylor, Einoti Matayan, Sia Mbishi, Edith Macha, Tara Mtuy,
International Centre for Eye Health, London School of Hygiene & Tropical Medicine, London, United Kingdom. · School of Health and Medical Sciences, City St George's, University of London, London, United Kingdom.
Key points
From the paper's conclusion- A cross-sectional study in Tanzania was undertaken to assess the feasibility of EMP as an initial glaucoma triage tool.
Abstract
Triaging access to glaucoma diagnostics could allow patients to receive earlier care to slow disease progression. There is a particular need in lower-resource settings where the cost and lack of portability of standard automated perimetry (SAP) restrict access. Eye movement perimetry (EMP) uses eye-tracking technology to provide a rapid assessment of the visual field using a tablet computer. A cross-sectional study in Tanzania was undertaken to assess the feasibility of EMP as an initial glaucoma triage tool. EMP hit rate correlated with SAP mean deviation in 370 eyes (Spearman's rank correlation coefficient, ρ = 0.441, p < 0.001) and graphical comparisons indicated good localisation of defects. In emulated triage of 232 participants, EMP exhibited very high (100.0%) sensitivity (95%CI: 95.5 to 100.0%) in identifying eyes with mean deviation ≤ -6 dB), meaning that a high EMP hit rate was strong evidence of a healthy visual field. However, specificity was 20.7% (95%CI: 15.0 to 27.8%), meaning that many individuals with no severe field defect would require SAP to confirm this. Specificity was limited by EMP test failure, which occurred in 75 of 480 eyes (15.6%), as well as export or processing failure which occurred in 35 eyes (7.3%). Participants preferred EMP to SAP testing and agreed that it was easy to perform. In a real-world setting, EMP rapidly and accurately identifies patients without a significant visual field defect. However, refinement is required to reduce the high number of unnecessary referrals or false positives for EMP to prove useful as a triage tool.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The TsiogkaSpaeth grid in Indian patients with primary open-angle glaucoma: A cross-sectional diagnostic accuracy study.Indian journal of ophthalmology · 2026
- Comparison of the Melbourne rapid fields-web device-independent online perimeter and the octopus 600 perimeter in glaucoma patients.Frontiers in ophthalmology · 2026
- Diagnostic accuracy and reliability of portable visual field-testing devices for detecting manifest glaucomatous visual-field loss: a systematic review and meta-analysis.BMC ophthalmology · 2026
- Design of a Pragmatic Randomized Controlled Trial for Comparing the Michigan Screening and Intervention for Glaucoma and Eye Health and Telemedicine Protocol with Usual Care for Disease Detection.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Complementary Visual Assessment: Validation of a High-Precision Eye-Tracking Kinetic Perimetry in the Evaluation of Visual Field Deficits in Hemianopia.Restorative neurology and neuroscience · 2026
- A Pilot Study to Compare a Portable Tablet Perimeter with Humphrey Field Analyzer in Patients with Neuro-Ophthalmic Disorders.Journal of binocular vision and ocular motility · 2026