Design of modified flattening filter for International Organization for Standardization recommended 147Pm beta source: a Monte Carlo approach.
Sujoy Chatterjee, Rolf Behrens, Rohit Yadav, Ashok K Bakshi, Balvinder K Sapra
RP&AD, Variable Energy Cyclotron Centre, Kolkata, 700064, India. · Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, Braunschweig, 38116, Germany.
Key points
From the paper's conclusion- The proposed filter design demonstrates a significant enhancement in dose-rate homogeneity at a calibration distance of 20 cm compared with the existing International Organization for Standardization (ISO)-recommended filter (ISO 6980 standard series).
Abstract
A modified beam-flattening filter design for the 147Pm beta source of the irradiation facility Beta Secondary Standard BSS-2 has been developed to achieve substantially improved dose-rate uniformity, targeting ±5% or better over the required phantom area. The study was performed using the Monte Carlo simulation codes EGSnrc and PHITS. The proposed filter design demonstrates a significant enhancement in dose-rate homogeneity at a calibration distance of 20 cm compared with the existing International Organization for Standardization (ISO)-recommended filter (ISO 6980 standard series). The dose-rate uniformity improved from approximately ±8% to nearly ±1% within a circular region of radius 7.5 cm, while simultaneously increasing the absolute central dose-rate by ~30%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Segmented G(E) Function Compensation Method for Gamma Dose Rate Meters Considering Asymmetric Error Distribution Across Energy RegionsSymmetry · 2026
- Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical192Ir and125I brachytherapy sources.Physics in medicine and biology · 2026
- Monte Carlo-based secondary dose check platform for the world's first ultra-compact upright proton therapy systemarXiv · 2026
- Distance-dependent influence of scoring voxel size on Monte Carlo dosimetry of an iridium-192 HDR brachytherapy sourceEPJ Web of Conferences · 2026
- Parameterizable salivary gland model for small-scale Monte Carlo radiopharmaceutical therapy dosimetry: evaluation of mouse and human model.Physics in medicine and biology · 2026
- Pulse-width-specific phase space modeling and reference beam characterization for UHDR electron LINAC in FLASH-RTPhysics in Medicine and Biology · 2026