Parameterizable salivary gland model for small-scale Monte Carlo radiopharmaceutical therapy dosimetry: evaluation of mouse and human model.
David P Adam, Tahir Yusufaly, Ian R Marsh, Remco Bastiaannet, Ana Kiess, Wesley E Bolch, Nouran Zaid, Anupriya Chhabra,
Department of Radiation Oncology, Mayo Clinic, 200 1st St SW, Rochester, Minnesota, 55905, United States. · Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, Maryland, 21287, United States.
Key points
From the paper's conclusion- This work develops a parametrizable 'Macro-to-Micro' (M2μ) model that demonstrates the consideration of small-scale dosimetry in comparison to conventional methods that typically assume uniform voxel or organ-level uptake.
Abstract
Standard of care RPT may result in dose-limiting side effects of the salivary glands include sialadenitis and xerostomia that are inconsistent with outcomes from external beam for equivalent ADs. This work develops a parametrizable 'Macro-to-Micro' (M2μ) model that demonstrates the consideration of small-scale dosimetry in comparison to conventional methods that typically assume uniform voxel or organ-level uptake. Anatomical features of the salivary gland are represented by annular structures (a centralized branching network of ducts, including excretory, lobar, interlobular) and small-scale voxels (intralobular ducts and acinar cells) with dimensions set to reproduce ex-vivo murine histopathology measurements and scaled up in size for extrapolation to humans. Simulations were performed by scoring and recording S-value histograms to the target ductal and acinar cells, for two beta emitters (177Lu, 131I) and one alpha emitter (225Ac). Four idealized activity distributions were created to assign activity to surface and volumes of the annuli, and GEANT4 v11 was used for radiation transport calculations. Comparisons against whole gland uniform spherical self-dose S-value calculations were conducted to validate the radiation transport and to highlight differences between M2μ and conventional dosimetry approaches. Analyses for both models showed greater S-value variation in comparison to the homogeneously distributed activity S-value calculation. The most notable result was that the calculated S-values differed between different branches, depending on the geometric size of the annuli. For the surrounding acinar cells, S-values from ductal cells decreased as a function of distance from the branching structures. High variability of S-values, depending on ductal cell dimensions as well as within the acinar cell distribution of the salivary gland highlights the potential clinical utility of small-scale approaches to RPT salivary gland dosimetry, contingent on clinical translation and validation. To this end, future work should further refine the model and incorporate small-scale activity distributions from pre-clinical and translational studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of internal doses from liver, kidneys, and urinary bladder irradiation during radionuclide clearance: Extension of S-values dataset for reference adult male and female mesh-type phantoms.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Mesh-based detailed human kidney models of the ICRP reference adults for radiopharmaceutical therapy dosimetry: microscale model of the renal cortex.Physics in medicine and biology · 2026
- Mesh-based detailed human kidney models of the ICRP reference adults for radiopharmaceutical therapy dosimetry: macroscale models.Physics in medicine and biology · 2026
- Impact of voxel size on hand dose calculations and dose-area histogram analysis for radiopharmaceutical operators.Radiological physics and technology · 2026
- The effect of tumor subregions in the evaluation of electron absorbed fraction and S factor.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Distance-dependent influence of scoring voxel size on Monte Carlo dosimetry of an iridium-192 HDR brachytherapy sourceEPJ Web of Conferences · 2026