Utilization of Point-Of-Care Testing (POCT) or troponin in patients with acute chest pain
H L Li, T H Lam, W S C Chan, C K Wong, T C Tsang, S H M Tsui, H F Tse, C C F Tam
Key points
From the paper's conclusion- Methods All patients presenting with acute chest pain to a hospital (a tertiary referral center in Hong Kong, China serving a population of 530,000) who underwent POCT TnI testing from 31/07/2023 to 30/06/2024 were included.
Abstract
Background Chest pain is a common complaint and encompasses potentially life-threatening pathologies including acute coronary syndrome (ACS), but its diagnosis and management might be delayed by relying on conventional laboratory troponin. Point-of-care-testing (POCT) troponin I (TnI) assays may represent an emerging option to facilitate rapid diagnosis and expedite interventional measures. There is a paucity of data describing the diagnostic performance of POCT TnI, particularly in the Asian population. Purpose To evaluate the association between POCT TnI and conventional laboratory testing as well as clinical outcomes. Methods All patients presenting with acute chest pain to a hospital (a tertiary referral center in Hong Kong, China serving a population of 530,000) who underwent POCT TnI testing from 31/07/2023 to 30/06/2024 were included. The turnaround time for POCT TnI assays were compared against that of conventional laboratory troponin T (TnT). Cut-offs used for elevated POCT include 4ng/L (1) and 22.9ng/L (99th percentile). It was compared against final diagnoses including ACS. We compared the area under curve for POCT TnI vs conventional TnT in association with ACS diagnosis. The association between elevated TnI and modified HEART (mHEART) score as well as ACS diagnosis were evaluated. Results A total of 996 patients (mean age 68years, 48% female) underwent POCT TnI. The median (interquartile range [IQR]) turnaround time were 10 (8–14) minutes vs 145 (121–169) minutes for POCT TnI and conventional TnT, respectively (P<0.001). The area under curve (95%CI) for POCT TnI and conventional TnT in association with ACS diagnosis were 0.879 (0.827–0.932) and 0.898 (0.863–0.93s), respectively (Fig.), and the difference was not significant (P=0.280). POCT TnI with level <4ng/L has a negative predictive value (NPV) of 98.8 (95% confidence interval [CI] 97.6 – 100.0) % for ACS diagnosis, comparable to that of TnT (98.9, 95% CI 98.0-100.0). The median (IQR) of mHEART score for patients with and without elevated POCT TnI were 6 (5–8) and 3 (2–4), respectively (P<0.001). When POCT TnI ≥ 99th percentile was combined with mHEART score ≥7, the positive predictive value for ACS diagnosis was 96.8% (95% CI 97.4-99.5). Conclusion(s) This is the first study evaluating utilization of POCT TnI testing in a large tertiary care centre in the Asia-Pacific region. Notably, a single measurement of POCT TnI<4ng/L has achieved 98.8% NPV for ACS. Our results highlight that POCT TnI testing represents an emerging, rapid, and readily available test that may facilitate diagnosis and management of patients with chest pain. The scope of implementing POCT TnI needs to be broadened.Figure 1
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- How high sensitivity cardiac Troponin Point of Care Testing can be integrated into existing or new pathways for chest pain assessment in the emergency department.Scandinavian journal of clinical and laboratory investigation · 2026
- Point-of-care high-sensitivity troponin testing for rapid chest pain triage in emergency primary care: preliminary efficacy findings from the OUT-POC StudyEuropean Heart Journal · 2026
- Validation of the eCL8000i point-of-care hs-cTnT assay: analytical performance and clinical utility in Chinese patientsJournal of Laboratory Medicine · 2026
- What is the diagnostic accuracy of different high sensitive point-of-care troponin assays for the assessments of patients presenting with chest pain at the emergency department?European Heart Journal · 2026
- Diagnostic accuracy of high-sensitivity point-of-care troponin assays in emergency department for patients presenting with chest pain: a systematic review.European journal of emergency medicine : official journal of the European Society for Emergency Medicine · 2026
- Impact of point-of-care high-sensitivity troponin testing on index admission and 30-day costs: secondary analysis of a randomised controlled trialEuropean Heart Journal · 2026