What is the diagnostic accuracy of different high sensitive point-of-care troponin assays for the assessments of patients presenting with chest pain at the emergency department?
B Backus, B L F Schueler, L E Van Daalen
Key points
From the paper's conclusion- Conclusion This systematic review indicates that hs-cTn POC assays are reliable for integration in the diagnostic pathways for patients presenting with chest pain at the ED, mainly when used for rapid rule out of ACS in patients with very low troponin values upon arrival.
Abstract
Background High-sensitivity cardiac troponin (hs-cTn) assays have significantly enhanced the diagnosis in patients suspected of Acute Coronary Syndrome (ACS). New hs-cTn point-of-care (POC) devices, with a turnaround time <20 minutes, may reduce time to diagnosis compared to central laboratory testing. However, it remains unclear whether the diagnostic accuracy of hs-cTn POC assays is comparable to that of central laboratory assays. Purpose We evaluated the diagnostic accuracy of four hs-cTn POC assays to assess their potential for clinical implementation at the emergency department (ED). Methods We conducted a search in PubMed Central on 20 November 2025. Studies were eligible for inclusion if they investigated adult patients (≥18 years) presenting with chest pain suggestive of ACS and evaluated commercially available hs-cTn POC devices. Studies had to report diagnostic accuracy (sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV)) as an outcome measure. The search strategy identified 436 articles, of which 11 were included in this systematic review, describing four currently commercially available hs-cTn POC devices. Results The described hs-cTn POC assays demonstrated the best diagnostic accuracy when applied as a single test rule-out upon arrival at the ED. The Atellica VTLi demonstrated a sensitivity > 98.8% for troponin values <7 ng/l, and a specificity of 97.7% for troponin values > 52 ng/l. The i-STAT assay showed a sensitivity of 99.8% for troponin values <5 ng/l and a specificity 96.4% at troponin values > 25 ng/l. The Pathfast achieved a sensitivity > 99.1% for troponin values <4 ng/l and a specificity > 96.4% for troponin values ≥ 90 ng/l. VTLI, Pathfast and TriageTrue were also tested using the 99th percentile with a 0+1/2/3 hour troponin protocol, reporting sensitivities of 64.8-100.0% and specificities of 85.8-96.0%. Conclusion This systematic review indicates that hs-cTn POC assays are reliable for integration in the diagnostic pathways for patients presenting with chest pain at the ED, mainly when used for rapid rule out of ACS in patients with very low troponin values upon arrival.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of high-sensitivity point-of-care troponin assays in emergency department for patients presenting with chest pain: a systematic review.European journal of emergency medicine : official journal of the European Society for Emergency Medicine · 2026
- A-041 Clinical Performance and Risk Classification Agreement of Point-of-Care i-STAT High-Sensitivity Troponin I Compared with Abbott Alinity hs-cTnI in ED Patients with Suspected Acute Coronary SyndromeClinical Chemistry · 2026
- Point-of-care high-sensitivity troponin testing for rapid chest pain triage in emergency primary care: preliminary efficacy findings from the OUT-POC StudyEuropean Heart Journal · 2026
- How high sensitivity cardiac Troponin Point of Care Testing can be integrated into existing or new pathways for chest pain assessment in the emergency department.Scandinavian journal of clinical and laboratory investigation · 2026
- Utilization of Point-Of-Care Testing (POCT) or troponin in patients with acute chest painEuropean Heart Journal · 2026
- Impact of point-of-care high-sensitivity troponin testing on index admission and 30-day costs: secondary analysis of a randomised controlled trialEuropean Heart Journal · 2026