Point-of-care high-sensitivity troponin testing for rapid chest pain triage in emergency primary care: preliminary efficacy findings from the OUT-POC Study
T R Johannessen, D Atar, S Halvorsen, J Munkhaugen, O M Vallersnes, A Bakken, A C K Larstorp
Key points
From the paper's conclusion- Together, these features enable faster identification of rule-out patients and may improve patient flow and chest pain management in busy clinics.
Abstract
Background High-sensitivity troponin testing at the point-of-care (POC) level may enable faster and more accurate assessment of chest pain in low-resource, out-of-hospital settings. The ongoing prospective OUT-POC study (One-hoUr Troponin using a high-sensitivity Point-Of-Care assay in emergency primary care), initiated in June 2025, aims to enrol 2,500 patients across six emergency primary care clinics in Norway. Purpose This interim analysis evaluates the triage efficacy of the study`s POC assay (TRIAGETRUE High Sensitivity Troponin I (hs-cTnI) Test) using the ESC 0/1-hour algorithm, comparing it to the standard-of-care central laboratory assay (Elecsys 5th-generation hs-cTnT) to identify discrepancies and assess potential safety concerns for patients classified as rule-out by the POC assay. Methods A prespecified interim analysis was performed on the first 300 participants enrolled at the largest study site. EDTA whole blood was collected for the POC assay, and lithium heparin samples were sent to the central laboratory via pneumatic tube for hs-cTnT analysis. The hs-cTnT results were blinded to the treating physicians. Major discrepancies were defined as cases in which the POC assay triaged a patient for direct rule-out, while the central laboratory assay classified the same patient as rule-in. Results During the first three months of inclusion, data were analysed from 308 patients with a median age of 55 years (IQR 42–69) and 47.4% (N=146) female. The POC assay triaged 65.6% (n=202) to 0-hour rule-out (<4 ng/L and ≥3 hours since symptom onset), compared with 45.5% (n=140) triaged by the hs-cTnT assay (<5 ng/L and ≥3 hours since symptom onset). The 0-hour rule-in rates were 4.2% for the POC assay (≥60 ng/L) and 2.6% for the hs-cTnT assay (≥52 ng/L). The POC assay also triaged 90 patients (29.2%) to the indeterminate observation group, requiring a repeat 1-hour sample. In comparison, the hs-cTnT assay would have required repeat sampling in 160 patients (51.9%), though 70 of these were not obtained due to blinded results. After the repeat sample, the POC 0/1-hour algorithm triaged 74.0% of the patients as rule-out, suggesting potential eligibility for discharge. No major discrepancies between the two assays were identified after a single sample. Technical error codes occurred in 3 of 308 patients (1.0%) during POC testing. Conclusions Compared with the standard-of-care central laboratory hs-cTnT assay, the TRIAGETRUE hs-cTnI POC assay provides a higher single-sample rule-out rate and a shorter turnaround time. Together, these features enable faster identification of rule-out patients and may improve patient flow and chest pain management in busy clinics. No safety concerns have been identified for the point-of-care assay, supporting continuation of the larger implementation study.Triage Efficacy after a single blood sample
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- What is the diagnostic accuracy of different high sensitive point-of-care troponin assays for the assessments of patients presenting with chest pain at the emergency department?European Heart Journal · 2026
- Diagnostic accuracy of high-sensitivity point-of-care troponin assays in emergency department for patients presenting with chest pain: a systematic review.European journal of emergency medicine : official journal of the European Society for Emergency Medicine · 2026
- How high sensitivity cardiac Troponin Point of Care Testing can be integrated into existing or new pathways for chest pain assessment in the emergency department.Scandinavian journal of clinical and laboratory investigation · 2026
- Can point-of-care high sensitivity troponin improve efficiency: a multisite US study.The American journal of emergency medicine · 2026
- Utilization of Point-Of-Care Testing (POCT) or troponin in patients with acute chest painEuropean Heart Journal · 2026
- A-041 Clinical Performance and Risk Classification Agreement of Point-of-Care i-STAT High-Sensitivity Troponin I Compared with Abbott Alinity hs-cTnI in ED Patients with Suspected Acute Coronary SyndromeClinical Chemistry · 2026