B-236 Operational Performance of the Roche Cobas Pro in a Pediatric Hospital

Justin Tsan, Brian Anaque, Kaitlyn Perez, Yi Xiao, Edward Leung

Key points

From the paper's conclusion
  • Overall workflow efficiency improved for calculated results using Navify middleware.

Abstract

Background The Roche Cobas Pro, consisting of an ion selective electrode (ISE) unit, c503 chemistry unit, and e801 immunochemistry unit, replaced the Ortho Vitros 5600 integrated chemistry analyzer. The Roche Navify middleware replaced the Data Innovations Instrument Manager middleware. This study evaluates the operational performance of both chemistry analyzers and middleware systems in a pediatric hospital setting. Methods Key operational metrics were reviewed for both analytical platforms. Data was collected from Cerner Laboratory Information System (LIS). Turnaround time (TAT) metrics for Chem 8, Chem 14, Lipid Panels, and high-volume immunoassays were evaluated. Sample and dead space volume requirements for Chem 14 and monthly cancellation rates due to insufficient volume were evaluated. Incidence of invalid calculated results (Anion Gap, % Iron Saturation) were evaluated. The timeframe for this study is between January to October 2025 for Vitros 5600 and October 2025 to January 2026 for Cobas Pro. Results Following implementation of Cobas Pro, average TAT increased from 43, 47, and 47 to 52, 55, and 61 minutes for Chem 8, and Lipid Panels respectively. Average TAT decreased from 63, 76, and 91 to 51, 63, and 64 minutes for Troponin, TSH, and Ferritin respectively. The changes are due to differences in onboard analysis time and delays caused by barcode read errors. Vitros MicroSlide test systems were between 6 to 12 minutes. Cobas Pro c503 test systems are standardized to 10 minutes. Vitros MicroWell test systems were between 20 to 55 minutes. Cobas Pro e801 test systems are between 9 to 27 minutes. Barcode read errors occurred at 4% and 14% onboard two Cobas Pro analyzer lines. The Vitros 5600 was not found to have any significant delays due to barcode read errors. Specimen cancellations rates decreased from 0.11% to 0.02%. For Chem 14 panels, Vitros 5600 analyzers required 141 µL of sample for testing. On c503 Cobas Pro analyzers, 78.3 µL of sample is required for testing utilizing MicroCup 13/16 sample containers. Calculated Anion Gap and % Iron Saturation were previously generated on Vitros 5600 but are now performed in Navify middleware. Rate of invalid Anion Gap results (<1) decreased from 0.47% to 0.11%, due to differing decimal rounding behavior and sodium, chloride, and bicarbonate assay interactions. The rate of incalculable % Iron Saturation increased from 1.54% to 3.16%. The increase is due to the transition from direct Total Iron Binding Capacity (transferrin-based) to Unbound Iron Binding Capacity reagents. Navify middleware enabled real-time updating of calculated results when assays required repeat testing, eliminating repeat testing of all associated assays when the calculation is performed by the instrument and decreased reagent use. Conclusion Transitioning from Vitros 5600 to Cobas Pro analyzers demonstrated an increase in turnaround time chemistry panels, a decrease in turnaround time for immunoassays, and a decrease in specimen cancellations due to insufficient sample volume. Calculated results demonstrated a decrease rate of invalid AGAP but an increase rate of invalid % Iron Saturation. Overall workflow efficiency improved for calculated results using Navify middleware.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers