B-043 Comparison of Turnaround Time of Beckman Coulter Power Processor and DxA 5000 Automated Systems
Oytun Portakal, Meryem Zengin Bulbul, Bedri Bera Eken, Samil Binici, Nazende Islak, Incilay Lay, Z Gunnur Dikmen
Key points
From the paper's conclusion- Conclusion Implementation of the DxA 5000 automation system significantly reduced turnaround time, increased processing capacity, and lowered preanalytical error rates.
Abstract
Background Turnaround time (TAT) is a key laboratory quality indicator reflecting the total time from sample receipt to result verification. Laboratory automation systems are designed to reduce human error, improve workflow efficiency, and shorten processing times by integrating preanalytical, analytical, and post-analytical phases. In February 2025, our institution transitioned from the Beckman Coulter Power Processor (PP) system to the next-generation Beckman Coulter DxA 5000 automation platform. This study aimed to compare the two systems in terms of TAT, processing efficiency, and preanalytical error rates. Methods This retrospective study was conducted at the Central Laboratory of Hacettepe University Hospitals. Data from September–October 2024 (Power Processor) and September–October 2025 (DxA 5000) were analyzed. Nine representative analytes from clinical chemistry and hormone panels were selected: total protein, creatinine, AST, total cholesterol, sodium, total bilirubin, TSH, cortisol, and vitamin B12. Turnaround time was defined as the interval from laboratory sample acceptance to final result verification. Acceptance-to-analysis time and analysis-to-verification time were also evaluated. Preanalytical error records (e.g., insufficient volume, hemolysis, clotting, labeling errors) were compared. Statistical analyses were performed using Student’s t-test, with p < 0.05 considered statistically significant. Results The DxA 5000 system demonstrated a significant reduction in TAT across all selected analytes compared to the Power Processor system (p < 0.0001). Significant decreases were observed in both acceptance-to-result and result-to-verification intervals (p < 0.0001). Average TAT reductions ranged between approximately 30–35% for clinical chemistry parameters and 12–24% for hormone assays. Sample processing capacity increased by 3.4%, while the overall sample rejection rate decreased by 7.3%. Operationally, the DxA 5000 system improved workflow efficiency through higher sample loading capacity, optimized automated rail design, and enhanced barcode and sample tracking stability, resulting in fewer preanalytical interruptions. Conclusion Implementation of the DxA 5000 automation system significantly reduced turnaround time, increased processing capacity, and lowered preanalytical error rates. These improvements may provide meaningful clinical benefits, particularly in emergency departments, intensive care units, and high-acuity clinical settings where rapid decision-making is essential. The DxA 5000 system represents a substantial advancement in laboratory workflow efficiency and operational reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-044 Investigation of the Effect of Shortening Centrifugation Time on Hormone Test Results with the Transition to DxA 5000 Automation SystemClinical Chemistry · 2026
- Improving Diagnostic Turnaround Time and Analytical Reliability in Clinical Biochemistry Laboratories: A Quality Management FrameworkInternational Journal of Latest Technology in Engineering Management & Applied Science · 2026
- B-241 AUTOMATING REPORTS TO MONITOR LABORATORY STABILITY AND DEFECTSClinical Chemistry · 2026
- B-038 Design and standardization of automated pre-analytical and post-analytical workflows to support growth in a high-volume clinical laboratoryClinical Chemistry · 2026
- B-236 Operational Performance of the Roche Cobas Pro in a Pediatric HospitalClinical Chemistry · 2026
- B-281 Comparison of Analytical Error Frequencies Between Closed-System and Open-System Clinical Chemistry AnalyzersClinical Chemistry · 2026