B-281 Comparison of Analytical Error Frequencies Between Closed-System and Open-System Clinical Chemistry Analyzers
Yeongsic Kim, Hanwool Cho, Hyunjung Kim, Soo Jung Lee, Soo-Young Kim, Hae Kyung Lee, Jehoon Lee
Key points
From the paper's conclusion- We analyzed repeat-testing data accrued over 13 years to determine whether analytical error frequencies differ between open- and closed-system clinical chemistry platforms.
Abstract
Background Clinical laboratories perform routine blood chemistry testing using analyzers that operate under either open- or closed-reagent systems. Closed systems use manufacturer-designated reagents to enhance standardization, whereas open systems permit the use of third-party reagents, potentially providing greater flexibility and reduced costs. However, systematic evaluations of laboratory errors in the analytical phase remain limited. We analyzed repeat-testing data accrued over 13 years to determine whether analytical error frequencies differ between open- and closed-system clinical chemistry platforms. Methods We retrospectively reviewed repeat-testing records for 7 serum chemistry analytes performed between July 2010 and June 2022. Of 14,022,171 total tests, 74,972 (0.53%) underwent repeat analysis triggered by delta check or panic check. The analytes were albumin, total protein, creatinine, glucose, sodium (Na), potassium (K), and chloride (Cl). The open-system analyzer was the Hitachi 7600 (Hitachi Ltd., Japan), and the closed-system analyzer was the Beckman Coulter AU5800 (Beckman Coulter, USA). An analytical error for repeated measurements was defined as a >10% difference between initial and repeat results. Error rates were compared across analytes and between analyzer systems using chi-square tests. Results The overall analytical error rate among retested samples was higher on the Hitachi 7600 than on the AU5800 (2.21% vs 0.95%). For sodium, analytical error rates were 0.24% (Hitachi 7600) and 0.18% (AU5800), with no significant difference. For chloride, both analyzers showed an identical error rate (0.24%). For creatinine, analytical error rates were relatively high (2.70% vs 2.39%) without a statistically significant difference between systems. For glucose, analytical error rates were 2.27% (Hitachi 7600) and 1.78% (AU5800), also without a significant difference. In contrast, albumin and total protein exhibited markedly lower error rates on the AU5800 (approximately 0.1%) than on the Hitachi 7600 (approximately 1.8%). For potassium, the AU5800 demonstrated a significantly lower error rate (approximately 0.75%) compared with the Hitachi 7600 (approximately 3.15%). Conclusion Analytical error frequencies varied by analyte and analyzer system. For certain analytes, the open-system platform demonstrated higher analytical error rates than the closed-system platform, suggesting that more stringent and proactive repeat-testing policies may be warranted for these assays. Conversely, for analytes with consistently low analytical error rates, reducing repeat-testing frequency may be justified.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-306 Prevalence, Causes, and Mitigation Strategies for Pre-analytical Errors Occurring at The University Hospital of the West Indies Chemistry LaboratoryClinical Chemistry · 2026
- Spectrum of Preanalytical Laboratory Errors in Clinical Biochemistry Laboratory in a Tertiary Care Center in Nepal.Kathmandu University medical journal (KUMJ) · 2025
- B-043 Comparison of Turnaround Time of Beckman Coulter Power Processor and DxA 5000 Automated SystemsClinical Chemistry · 2026
- Three consecutive failures, one uncertain verdict: A simulation-based reassessment of accreditation-restriction rules in clinical chemistryRevista Romana de Medicina de Laborator · 2026
- B-302 Body Fluids as Complex Analytical Metrices: Challenges in Validation and Analytical Performance of Automated Biochemistry AnalyzersClinical Chemistry · 2026
- A-282 Analysis of Recheck and Revision Rates Across the Life Cycle of High Volume Chemistry Analyzers: Informing Lab Stewardship and Asset ManagementClinical Chemistry · 2026