B-208 Comparison of Human Immunoglobulins and Free Light Chain Testing Workflow and Efficiency on The Optilite Standalone Analyzer and An Integrated Chemistry Analyzer with Automation

Steve Stone, Anu Maharjan, Michael Walczak, Ben Fronkier, Morgan Butterfield

Key points

From the paper's conclusion
  • Conclusion The Optilite standalone platform demonstrated equivalent, or better, immunoglobulin and FLC testing efficiency and turnaround time as compared to the integrated analyzer.

Abstract

Background Fully automated, integrated chemistry analyzers are designed for menu consolidation, high throughput testing and laboratory efficiencies. However, are these systems best suited for human immunoglobulins and free light chain (FLC) assays? The objective of this study was to compare the process workflow, resources required and efficiencies between the Binding Site Optilite® analyzer (Optilite) (a standalone automated platform) and the Abbott Alinity ci system (Alinity) (with ACCELERATOR a3600 automation) for immunoglobulins and FLC assays. Methods Argent Global Services, an independent consulting company, performed a side-by-side, observational time and motion study, observing testing activities for both systems over a period of five days. The assays included Human Kappa/Lambda free light chains (FLC) and immunoglobulins IgA, IgG and IgM. The FLC reagents utilized on the Alinity were third-party assays from Diazyme Laboratories. Routine and procured known high-result specimens were analyzed daily on both the Optilite and the Alinity ci. The observed activities included testing, dilutions, maintenance (daily, weekly, and monthly), quality control, calibration, and troubleshooting events. The data are presented as weighted averages. Results The total times, for FLC-only results, were 34.1 minutes on Alinity and 37.7 minutes on Optilite. For immunoglobulin only samples, Alinity averaged 41.8 minutes vs. 32.4 minutes on Optilite. When both FLC and immunoglobulin were tested, turnaround was 63.8 minutes on Alinity and 40.9 minutes on Optilite—a 36% faster result with Optilite. Instrument availability also differed significantly: Alinity required 126.5 minutes of planned daily maintenance compared with 31.5 minutes for Optilite, an 75.1% reduction. Of 76 routine FLC samples, 29 were below the detectable range for either kappa or lambda on Alinity, while there were only 11 on Optilite, showing a 62% decrease. For high result samples requiring dilutions, Alinity only performs up to two auto-dilutions, before manual intervention is required. On the other hand, the Optilite auto-dilutes until complete. For samples that required three additional dilutions to achieve a result, the total testing took 108.7 minutes on Alinity, including manual intervention, while only 81.9 minutes on Optilite with no manual intervention, showing 24.7% faster testing with no additional hands-on time. Conclusion The Optilite standalone platform demonstrated equivalent, or better, immunoglobulin and FLC testing efficiency and turnaround time as compared to the integrated analyzer. The total time to results for specimens that required both FLC and immunoglobulins took much longer on Alinity compared to Optilite. This was due in part to the automation workflow and delays, and system downtime. The time to result for samples requiring additional dilutions to achieve a reportable result were also faster on the Optilite. Due to the extended reportable range(s) on Optilite, there were fewer results below the detectable range compared to Alinity, increasing the ability to calculate the free light chain ratio, and enabling more complete sFLC reporting to support timely patient management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers