405 The Effect of Anticoagulant Volume Adjustment in 3.2% Sodium Citrate Evacuated Tubes on the Viability of Prothrombin Time (PT), Partial Thromboplastin Time (PTT), and Fibrinogen Assay Among High Hematocrit Ethylenediaminetetraacetic Acid (EDTA) Tube Samples in the Philippines
Persus Atienza, Juan Diego Foronda, Allana Jasmine Tan, Julianne Paige Ng, Marianne Nicole Arcilla, Ron Christian Sison, Xandro Alexi Nieto, Canellie Canlas-Ocsona
Key points
From the paper's conclusion- In contrast, no statistically significant differences were observed between adjusted and unadjusted tubes for PTT (p = 0.053) and fibrinogen assay (p = 0.355).
Abstract
Introduction/Objective High hematocrit levels can compromise the accuracy of coagulation test results in evacuated tubes containing 3.2% sodium citrate, an anticoagulant that reversibly binds calcium ions through chelation. In cases of elevated hematocrit levels, plasma volume decreases, resulting in an excess blood-to-anticoagulant ratio and increased calcium chelation, falsely prolonging clotting times. The Clinical and Laboratory Standards Institute (CLSI) recommends adjusting the anticoagulant volume when a patient’s hematocrit is ≥ 55% (0.55 L/L) to maintain the blood-to-anticoagulant ratio. This study evaluates this recommendation on coagulation test outcomes, specifically prothrombin time (PT), partial thromboplastin time (PTT), and Clauss fibrinogen assay. Methods/Case Report A total of five participants, aged 18 to 75 years, with hematocrit levels ranging from 55% to 65% (0.55 L/L to 0.65 L/L) were analyzed. Results The laboratory results demonstrated that the mean PT in the adjusted tubes was lowered by 3.88 seconds (p < 0.001) compared to the unadjusted tubes. In contrast, no statistically significant differences were observed between adjusted and unadjusted tubes for PTT (p = 0.053) and fibrinogen assay (p = 0.355). Conclusion These findings suggest that citrate adjustment for PT is statistically significant, whereas being statistically insignificant for PTT and fibrinogen assay.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of sodium citrate and magnesium sulphate anticoagulation on platelet parameters measured on the Alinity hq analyzer.Laboratory medicine · 2026
- Impact of blood collection tubes on thrombin generation assay results: a comparison of citrate and CTADScientific Reports · 2026
- A-249 Evaluation of three cartridge-based analyzers for viscoelastic testingClinical Chemistry · 2026
- 301 Stability of Routine Coagulation Assays at Room TemperatureAmerican Journal of Clinical Pathology · 2026
- Re-evaluating haemolysis rejection criteria for PT, aPTT, and D-dimer testing: evidence from paired clinical samples on the CN-3000 analyser.Advances in laboratory medicine · 2026
- Simulation Study on Preanalytical Variables in Coagulation Testing: Interference Effects and Threshold Determination of Hemolysis, Lipemia, Icterus and Insufficient Sample Volume.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2026