301 Stability of Routine Coagulation Assays at Room Temperature
Boles AKhnouKh, Sasha Palo-Cabase, Trina Ibis, Bilal Abdou
Key points
From the paper's conclusion- In routine practice, samples are often stored at room temperature (RT) prior to analysis, while stability limits vary between assays.
Abstract
Introduction/Objective Pre-analytical delays and storage conditions can affect coagulation test results. In routine practice, samples are often stored at room temperature (RT) prior to analysis, while stability limits vary between assays. This study evaluated the stability of commonly used coagulation tests under RT conditions. Methods/Case Report Residual citrated plasma samples (n ≥ 30 per assay) were tested for APTT, thrombin time (TT), D-Dimer, Anti-Xa (LMWH), and fibrinogen (QFA). Samples were analyzed at baseline and after RT storage (8 hours for APTT; 24 hours for others). Stability was assessed using linear regression and percent change with acceptance limits of ± 15% or ± 20%. Results APTT remained stable up to 8 hours despite mild proportional bias. Fibrinogen showed overall stability at 24 hours with borderline changes. TT demonstrated significant degradation and failed stability criteria at 24 hours. D-Dimer and Anti-Xa showed acceptable regression trends but increased variability, particularly at low concentrations, affecting consistency with acceptance limits. Conclusion APTT is stable for up to 8 hours, while fibrinogen is generally stable up to 24 hours with minor limitations. TT is not stable at 24 hours and should be tested promptly. Variability in D-Dimer and Anti-Xa warrants cautious interpretation. Assay-specific stability limits are essential to ensure reliable results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Preanalytical Storage Time and Air Exposure on ROTEM and Coagulation Sample Stability.Advances in hematology · 2026
- Preanalytical stability of aPTT and anti-Xa levels for therapeutic unfractionated heparin monitoring: a systematic review and critical appraisal using CRESS criteria.Clinical chemistry and laboratory medicine · 2026
- Evaluation of UNI-VAC serum separator, ethylenediaminetetraacetic acid, sodium citrate, and sodium fluoride tubes: A comparison with Becton, Dickinson and Company Vacutainer tubes.PloS one · 2026
- A-183 Standardizing Specimen Stability Studies for Venous Whole Blood, Serum, and Plasma: A Practical Framework with Analysis Methods, Acceptance Criteria, and Worked ExamplesClinical Chemistry · 2026
- Effects of storage temperature and delayed analysis on routine biochemical and haematological test resultsScientific Reports · 2026
- Concentration-dependent and platform-specific interference of argatroban and bivalirudin in routine coagulation assays.Thrombosis journal · 2026