Modeling of novel converging beam radiotherapy system in Geant4 Monte Carlo simulation.
Dongyoen Lee, Reza Reiazi, Dirk Alan Bartkoski, Aviad Schori, Benjamin Abraham Insley, Leonard Che Fru, Ramesh Tailor, Michael Kleckner,
MD Anderson Division of Radiation Oncology, 1515 Holcombe Blvd, Houston, 77030, United States. · Radiation Physcis, The University of Texas MD Anderson Cancer Center, 1515 Pressler St, Houston, Texas, 77030-4000, United States.
Key points
From the paper's conclusion- In this study, CRnR’s converging beam radiotherapy system was implemented in Geant4 to demonstrate the device operation and characterize its physical and dosimetric outputs.
Abstract
PURPOSE: A Geant4-based model was created to simulate radiation transport within a novel radiotherapy system developed by Convergent Radiotherapy and Radiosurgery (Convergent RnR; Haifa, Israel). This treatment device incorporates a Bragg-diffraction X-ray lens to focus X-rays from a conventional X-ray tube towards a small but finite focal spot with quasi-monoenergetic photons. METHODS: The simulation model included an X-ray tube and a CRnR focusing lens consisting of single-crystal aluminum tiles. To validate the Geant4 model of this device, transverse and longitudinal in-air and in-water dose distributions from the converging beam field were calculated and compared to radiochromic film measurements. RESULTS: The implemented Monte Carlo (MC) simulation model predicted a mean photon energy of 53.96 keV and showed agreement within 0.5% when compared with the SpekPy calculation. Both the simulation and experiment produced an attenuation characteristics of 3.2 mm Al. In-water tissue maximum ratios showed percentage differences ≤3.03% at depths of 5, 10, 30, 40, 50, 60, and 70 mm. Exceptions were observed at 20, 80, and 85 mm, likely due to film positioning uncertainty. A gamma analysis of in-water scanning dose distributions demonstrated a >96% pass rate for the 2%/2 mm criterion and >99% for the 3%/3 mm criterion across all focal depths. CONCLUSIONS: In this study, CRnR's converging beam radiotherapy system was implemented in Geant4 to demonstrate the device operation and characterize its physical and dosimetric outputs. The MC simulation implemented in this work successfully demonstrated converging dose distributions with Bragg-diffraction physics, which were in good agreement with radiochromic film measurements. This simulation model may be used to further refine the converging beam system design for clinical implementation, including validation of the treatment planning system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Radiotherapy Dataset to Cherenkov Dose Map: A Digital Linac Monte Carlo Simulation PipelinearXiv · 2026
- Emission-associated energy deposition and Cherenkov-dose proportionality in megavoltage photon beamsarXiv · 2026
- Monte Carlo simulation of the ISOLPHARM gamma camera for Ag-111 imagingJournal of Instrumentation · 2026
- Evaluation of GPU-accelerated Monte Carlo beam and agility MLC modeling in the Monaco treatment planning system.Journal of applied clinical medical physics · 2026
- A convergent electron beam approach for small-field irradiation with reduced bremsstrahlung.Physics in medicine and biology · 2026