Spectacular — a modular DAQ system for microdosimetry
Matthias Knopf, Simon Waid, Daniel Radmanovac, Sebastian Onder, Richard Thalmeier, Peter Fischer, Stefan Gundacker, Claudio Verona,
Key points
From the paper's conclusion- To address this, a modular data acquisition (DAQ) system was developed to accelerate the design of custom readout electronics and sensor characterization in microdosimetry and related spectroscopic applications.
Abstract
Particle therapy using light ions like protons, helium-ions or carbon-ions enables precise tumor targeting with enhanced biological effectiveness while minimizing damage to healthy tissue. Successful treatment planning depends not only on the absorbed dose but also on quality of the radiation, as quantified by the linear energy transfer (LET). Microdosimetry provides a direct experimental determination of such quantities by measuring the energy deposited per incoming particle in micrometer-sized solid-state detectors representing the relevant biological scales. However, the small signal amplitudes and high particle rates in therapeutic ion beams (up to 10 10 s -1 ) challenge existing readout systems, which are not sufficiently optimized for reliable operation with respect to pileup and signal-to-noise ratio (SNR). To address this, a modular data acquisition (DAQ) system was developed to accelerate the design of custom readout electronics and sensor characterization in microdosimetry and related spectroscopic applications. Centered around a Xilinx Zynq system-on-chip, it combines real-time processing, high-bandwidth streaming, and high-resolution digitization (16 bit at 100 MSa s -1 ) to enable advanced digital signal processing. The platform integrates programmable power supplies, a bias-voltage filter, test-pulse generators, and flexible I/O. Detector and preamplifier front-ends are hosted on interchangeable daughter boards connected via a standardized interface, allowing different hardware configurations and readout algorithms to be evaluated on the same platform. The Spectacular DAQ system was successfully tested at the MedAustron ion therapy facility with custom charge-sensitive amplifiers and a diamond microdosimeter. First results demonstrate the feasibility and provide a proof-of-concept for potential future applications in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoringarXiv · 2026
- Scintillating Micro-Probe Detectors for Conventional and FLASH Proton Dosimetry: Optical Transport and Geometry Modeling.Bioengineering (Basel, Switzerland) · 2026
- Experimental verification of clinical dose and LET maps for LET-informed proton therapy.Physics in medicine and biology · 2026
- Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR BrachytherapyarXiv · 2026
- Development of an FPGA-Based Readout System and Functional Characterization of a Custom NSX1 ASIC for X-ray instrumentationarXiv · 2026
- Development of double-clad Qdot-based microstrip detector for Spatially Fractionated Radiotherapy dosimetryJournal of Physics: Conference Series · 2026