Scintillating Micro-Probe Detectors for Conventional and FLASH Proton Dosimetry: Optical Transport and Geometry Modeling.
Shiv K Subedi, Sree Bash Chandra Debnath
Stritch School of Medicine, Loyola University Chicago, Maywood, IL 60153, USA.
Key points
From the paper's conclusion- These findings demonstrate that fiber insertion geometry and volumetric optical scattering significantly influence the dose-rate response and saturation threshold of scintillating micro-probes.
Abstract
Optical fiber-based inorganic scintillating detectors (ISDs) are increasingly investigated for radiation therapy applications, including microbeam and ultra-high-dose-rate dosimetry. Accurate characterization of these compact detectors is particularly important for proton beams delivered under high-flux and FLASH conditions. Simplified analytical and ray-tracing models can estimate detector saturation limits but may inadequately account for internal optical scattering and the fiber insertion geometry within the scintillating volume, leading to inaccurate estimates of the effective sensitive volume and dose-rate response. In this study, we developed a detailed computational framework that explicitly models the fiber-scintillator geometry and volumetric optical photon transport. Five detector geometries with different sensitive volumes were evaluated under 25 and 230 MeV proton irradiation using a fully volumetric GATE Monte Carlo optical transport model incorporating intra-dosimeter optical scattering. The results revealed a clear inverse relationship between detector sensitive volume and maximum measurable dose rate before saturation. At 25 MeV, the maximum measurable dose rate (D˙max) ranged from 364.5 ± 7.6 Gy/s for the smallest detector to 13.5 ± 0.2 Gy/s for the largest detector, while at 230 MeV, it ranged from 392.6 ± 8.1 Gy/s down to 15.6 ± 0.3 Gy/s at 230 MeV, respectively. These findings demonstrate that fiber insertion geometry and volumetric optical scattering significantly influence the dose-rate response and saturation threshold of scintillating micro-probes. Accurate modeling of these effects is therefore essential for optimizing detector geometry, establishing reliable quantitative dosimetry across conventional and proton-FLASH dose-rate regimes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Scintillation Fiber-Optic Detectors for Dosimetry of 60 MeV Proton Beam.Materials (Basel, Switzerland) · 2026
- A scintillator-based approach to spatial and temporal dosimetry in UHDR electron irradiationJournal of Physics: Conference Series · 2026
- Comparison of radiation damage effects in plastic scintillators after ultra-high dose rate irradiations of 9-MeV electrons, 200-MeV electrons, and 87-MeV protonsJournal of Physics: Conference Series · 2026
- Performance evaluation of a new type of commercial silicon detectors for photon beam dosimetryJournal of Applied Clinical Medical Physics · 2026
- Comparison of percentage depth dose measurements obtained with three detector technologies and Monaco TPS calculations in a 1 × 1 cm² small photon field.Biomedical physics & engineering express · 2026
- Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR BrachytherapyarXiv · 2026