Optimization of hemolysis index thresholds for biochemical and immunoassays.
Anne Marie Dupuy, Delphine Tabone, Caroline Coulon, Marion Morena, Jean Paul Cristol
Laboratoire de Biochimie et Hormonologie, CHU Montpellier, Univ Montpellier 1, Montpellier, France.
Key points
From the paper's conclusion- Our study allowed us to supplement the data provided by the manufacturer and to optimize the thresholds for interference with hemolysis management of hemolyzed samples.
Abstract
BACKGROUND: Our study aimed at establishing analyte-specific hemolysis-index thresholds on 18 chemistry assays to avoid re-sampling on Atellica© Solution (Siemens Healthcare Diagnostics, Los Angeles, CA, USA). METHODS: We focused on the analytes which showed the highest degree of hemolysis interference at one or two baseline concentrations for the following 18 analytes: ALT (alanine aminotransferase), ammonium, AST (aspartate aminotransferase), CK (creatine kinase), creatinine, folates, FSH (follicle stimulating hormone), GGT (γ-glutamyltransferase), Hp (haptoglobin), iron, insulin, LD (lactate dehydrogenase), lipase, potassium, urea, uric acid, vitamins B12, and D. Interference was quantified as a percentage difference from the Hb-free baseline sample. Each calculated bias was compared to the four cutoffs: 10%Δ, analytical change limit, total change limit, or reference change limit. RESULTS: Analytes that did not exceed the predefined allowable-bias criterion for hemolysis included creatinine, FSH, GGT, iron, urea, uric acid, and vitamin B12. Among the affected analytes, the largest positive and negative biases were observed for AST, folates, LD, and potassium. The principal quantitative optimized thresholds for the hemolysis-sensitive analytes were AST, folates, iron, potassium, and LD tests. CONCLUSION: Our study allowed us to supplement the data provided by the manufacturer and to optimize the thresholds for interference with hemolysis management of hemolyzed samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of Hemolysis, Icterus, and Lipemia Interference in 14 Clinical Chemistry and 5 Immunoassay Parameters.Clinical laboratory · 2026
- A-214 Hemolysis Interference for ALT and AST with Pyridoxal Phosphate Activation on 2 Different Roche Chemistry AnalyzersClinical Chemistry · 2026
- Simulation Study on Preanalytical Variables in Coagulation Testing: Interference Effects and Threshold Determination of Hemolysis, Lipemia, Icterus and Insufficient Sample Volume.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2026
- Analytical performance of CSF, pleural, and peritoneal fluids on the Siemens Atellica CH930.Clinical biochemistry · 2026
- When Hemolysis Misleads: Implications for the Clinical Interpretation of Enzyme Activities in Pediatric Samples.Medicina (Kaunas, Lithuania) · 2026
- Re-evaluating haemolysis rejection criteria for PT, aPTT, and D-dimer testing: evidence from paired clinical samples on the CN-3000 analyser.Advances in laboratory medicine · 2026