Talanta

Single-step determination of cardiac troponin molecular form ratios using multiparametric SH-SAW biosensing.

Szonja Rokonay, Jun Kondoh, Róbert E Gyurcsányi, László F Simon

Department of Inorganic and Analytical Chemistry, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3., Budapest, H-1111, Hungary; BME-Lendület Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Műegyetem rkp. 3., Budapest, H-1111, Hungary. · Graduate School of Science and Technology, Shizuoka University, Hamamatsu, 432-8561, Japan. Electronic address: kondoh.jun@shizuoka.ac.jp.

Key points

From the paper's conclusion
  • Combined with composition-dependent calibration, this approach provides a framework for determining both the troponin molecular composition and total concentration.

Abstract

Cardiac troponins are definitive biomarkers of acute myocardial infarction (AMI). However, current diagnostic assays quantify the overall immunoreactive concentration of these biomarkers without distinguishing between their different circulating forms. After myocardial injury, troponins are primarily released as cTnI-T-C complexes, which gradually dissociate into subunits, such as free cTnI. Previous studies have suggested that the cTnI:cTnI-T-C ratio may function as a "molecular clock" for estimating the onset of AMI, necessitating precise analytical differentiation between the different troponin forms. Herein, we present a shear horizontal surface acoustic wave (SH-SAW) biosensor platform that can quantify these ratios in a single measurement. This approach leverages the simultaneous amplitude and phase changes in acoustic wave propagation, which provide complementary information on the spatial extent and acoustic properties of surface-bound molecular layers. The layer parameter (lp), derived from the attenuation and velocity responses, was used to characterize the surface-bound protein layer. Using a guided configuration and analytical multiparametric model, we determined the layer parameters for intact cTnI-T-C, free cTnI, and their mixtures. The layer parameter exhibited a systematic nonlinear dependence on the cTnI:cTnI-T-C molar ratio, enabling the estimation of this ratio without prior knowledge of the total protein concentration. Combined with composition-dependent calibration, this approach provides a framework for determining both the troponin molecular composition and total concentration. Beyond its potential application in the temporal characterization of AMI, the proposed strategy may be extended to other biomarkers for which discrimination between molecular forms provides diagnostically relevant information.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.