Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction.

Jingjing Zhang, Lan Wang, Qian Peng, Yongheng Li, Xiyu He, Jian Liu, Wei Sun, Lianhui Wang,

State Key Laboratory of Flexible Electronics (LoFE), Jiangsu Key Laboratory of Smart Biomaterials and Theranostic Technology, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, Nanjing210023, China. · Department of Cardiology, Geriatric Hospital of Nanjing Medical University, Nanjing210029, China.

Observational · n=94

Key points

From the paper's conclusion
  • This reliable one-pot SERS platform bridges ultra-sensitive detection and rapid portable readout, holding promise as a potential tool for future decentralized cardiovascular POC diagnostics.

Abstract

Rapid clinical decision-making for acute myocardial infarction (AMI) relies on the timely and precise assessment of cardiac biomarkers. However, detecting cardiac troponin I (cTnI), as the gold-standard biomarker for AMI, with both laboratory-grade sensitivity and rapid clinical turnaround remains a formidable challenge in point-of-care (POC) settings. To address this, we develop a one-pot surface-enhanced Raman scattering (SERS) aptasensor that integrates aptamer-mediated cTnI recognition, catalytic hairpin assembly (CHA) amplification, and plasmonic hotspot assembly. The assay supports two kinetic operating modes within the same assay: a 60-min high-sensitivity mode with a serum limit of detection (LOD) of 53.58 fg/mL and a 20-min rapid-triage mode with an LOD of 14.25 pg/mL, below the clinical decision threshold of 40 pg/mL. In a cohort of 100 clinical serum samples, the bootstrap optimism-corrected diagnostic accuracy was 91.3% for the SERS aptasensor, significantly outperforming conventional ELISA (77.8%). In a subset of 94 subjects with available routine cTnT results, the SERS-cTnI assay achieved an area under the receiver operating characteristic curve (AUC) of 0.988, comparable to that of the hospital's routine chemiluminescence cTnT assay (0.976), supporting its potential as a complementary diagnostic tool for cTnI-based AMI assessment. Furthermore, compatibility with a handheld Raman spectrometer was evaluated in an independent validation cohort (n = 36), achieving 97.2% accuracy using only 4 μL of serum within 20 min following serum preparation. This reliable one-pot SERS platform bridges ultra-sensitive detection and rapid portable readout, holding promise as a potential tool for future decentralized cardiovascular POC diagnostics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers