Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction.
Jingjing Zhang, Lan Wang, Qian Peng, Yongheng Li, Xiyu He, Jian Liu, Wei Sun, Lianhui Wang,
State Key Laboratory of Flexible Electronics (LoFE), Jiangsu Key Laboratory of Smart Biomaterials and Theranostic Technology, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, Nanjing210023, China. · Department of Cardiology, Geriatric Hospital of Nanjing Medical University, Nanjing210029, China.
Key points
From the paper's conclusion- This reliable one-pot SERS platform bridges ultra-sensitive detection and rapid portable readout, holding promise as a potential tool for future decentralized cardiovascular POC diagnostics.
Abstract
Rapid clinical decision-making for acute myocardial infarction (AMI) relies on the timely and precise assessment of cardiac biomarkers. However, detecting cardiac troponin I (cTnI), as the gold-standard biomarker for AMI, with both laboratory-grade sensitivity and rapid clinical turnaround remains a formidable challenge in point-of-care (POC) settings. To address this, we develop a one-pot surface-enhanced Raman scattering (SERS) aptasensor that integrates aptamer-mediated cTnI recognition, catalytic hairpin assembly (CHA) amplification, and plasmonic hotspot assembly. The assay supports two kinetic operating modes within the same assay: a 60-min high-sensitivity mode with a serum limit of detection (LOD) of 53.58 fg/mL and a 20-min rapid-triage mode with an LOD of 14.25 pg/mL, below the clinical decision threshold of 40 pg/mL. In a cohort of 100 clinical serum samples, the bootstrap optimism-corrected diagnostic accuracy was 91.3% for the SERS aptasensor, significantly outperforming conventional ELISA (77.8%). In a subset of 94 subjects with available routine cTnT results, the SERS-cTnI assay achieved an area under the receiver operating characteristic curve (AUC) of 0.988, comparable to that of the hospital's routine chemiluminescence cTnT assay (0.976), supporting its potential as a complementary diagnostic tool for cTnI-based AMI assessment. Furthermore, compatibility with a handheld Raman spectrometer was evaluated in an independent validation cohort (n = 36), achieving 97.2% accuracy using only 4 μL of serum within 20 min following serum preparation. This reliable one-pot SERS platform bridges ultra-sensitive detection and rapid portable readout, holding promise as a potential tool for future decentralized cardiovascular POC diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- T7 Ribonucleic Acid Polymerase-Triggered CRISPR/Cas13a and Branched HCR Cascade Amplification with Machine Learning for SERS Detection of Cardiac Troponin IACS Applied Materials & Interfaces · 2026
- Tetrahedral DNA Framework-Bridged Aptasensing Method for Ultrasensitive Determination of Cardiac Troponin I.Chemical & biomedical imaging · 2026
- Dual-channel surface-enhanced Raman immunoassay for simultaneous determination of atrial-fibrillation-associated NT-proBNP and high-sensitivity cardiac troponin I in artificial serum.Analytical methods : advancing methods and applications · 2026
- An Ultrasensitive Fluorescent Immunoassay Based on R-CDs@SiO2 Nanoparticles for Detection of Cardiac Troponin I.Applied biochemistry and biotechnology · 2026
- High-entropy nanozymes integrated with CRISPR/Cas12a cascade amplification for highly sensitive point-of-care detection of cardiac troponin I.Biosensors & bioelectronics · 2026
- A 0/2-Hour Algorithm Using a Novel Point-of-Care High-Sensitivity Cardiac Troponin I Assay for Suspected Myocardial Infarction.American heart journal · 2026