Tetrahedral DNA Framework-Bridged Aptasensing Method for Ultrasensitive Determination of Cardiac Troponin I.
Jiaqi Cai, Wenshuai Zhou, Liang Gao, Xiaolin Yang, Meng Li, Chengxiao Zhang, Honglan Qi
Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P. R. China. · Xi'an People's Hospital (Xi'an Fourth Hospital), Xi'an, 710068, P. R. China.
Key points
From the paper's conclusion- This work demonstrated that the combination of the specific TDF-aptamer and microsized Ab2-biotin•SA@MB-Ru1 within the imaging method can enhance the specific recognition and detection sensitivity for cTnI, which is promising for AMI diagnosis.
Abstract
The development of a sensitive and accurate method for the determination of cardiac troponin I (cTnI), as an ideal biomarker of acute myocardial infarction (AMI), is critical for the early diagnosis of AMI. In this work, a tetrahedral DNA framework (TDF)-bridged aptasensing method was proposed for the ultrasensitive determination of cTnI via electrogenerated chemiluminescence (ECL) and fluorescence imaging methods, in which a specific anti-cTnI aptamer-tagged tetrahedral DNA framework (TDF-aptamer) was designed as a capture probe by incorporating a specific aptamer against cTnI within the three-dimensional TDF. The TDF-aptamer was modified onto a gold electrode surface through the Au-S bond, providing a specifically captured platform for cTnI with a 3D binding space at the nanoscale. One microsized signal probe (Ab2-biotin•SA@MB-Ru1) was synthesized by using magnetic Fe3O4 as carriers to load a large amount of ruthenium complex and a specific cTnI antibody. After the sandwich assay among the modified TDF-aptamer, cTnI, and the signal probe, both ECL and fluorescence signals were recorded for the cTnI assay with desirable selectivity and high sensitivity (linear range of 5 to 80 pg/mL using ECL intensity detection and 0.5 to 500 pg/mL using ECL and fluorescence imaging methods). This work demonstrated that the combination of the specific TDF-aptamer and microsized Ab2-biotin•SA@MB-Ru1 within the imaging method can enhance the specific recognition and detection sensitivity for cTnI, which is promising for AMI diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasensitive Electrochemiluminescence Aptasensor With DNA Nanotetrahedron Amplification for Multilevel Detection of cTnI From Cells to Patients.Advanced healthcare materials · 2026
- Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction.ACS sensors · 2026
- Single-Probe Dual-Mode Biosensor for Cross-Validated Detection of cTnI in Myocardial Damage Evaluation.ACS sensors · 2026
- High-entropy nanozymes integrated with CRISPR/Cas12a cascade amplification for highly sensitive point-of-care detection of cardiac troponin I.Biosensors & bioelectronics · 2026
- Electrochemical cardiac troponin I immunosensor platform integrated with electrochemically deposited Au nanoparticles decorated PtNi bimetallic sponge-like structures.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- An Ultrasensitive Fluorescent Immunoassay Based on R-CDs@SiO2 Nanoparticles for Detection of Cardiac Troponin I.Applied biochemistry and biotechnology · 2026