Dual-channel surface-enhanced Raman immunoassay for simultaneous determination of atrial-fibrillation-associated NT-proBNP and high-sensitivity cardiac troponin I in artificial serum.
Lijun Qin, Yanhong Mou, Yan Guo, Zhengke Ma
Department of Cardiology, Lanzhou University Second Hospital, Lanzhou, 730030, China. lijunqin0907@163.com.
Key points
From the paper's conclusion- We developed a single-chamber, dual-channel surface-enhanced Raman scattering (SERS) immunoassay that combines antibody-functionalised magnetic capture beads with Au@Ag nanotags encoded by 4-mercaptobenzonitrile at 2227 cm-1 and 4-mercaptobenzoic acid at 1077 cm-1.
Abstract
Atrial fibrillation is associated with myocardial wall stress and low-grade injury, yet parallel measurement of N-terminal pro-B-type natriuretic peptide (NT-proBNP) and high-sensitivity cardiac troponin I (hs-cTnI) generally requires separate immunoassays. We developed a single-chamber, dual-channel surface-enhanced Raman scattering (SERS) immunoassay that combines antibody-functionalised magnetic capture beads with Au@Ag nanotags encoded by 4-mercaptobenzonitrile at 2227 cm-1 and 4-mercaptobenzoic acid at 1077 cm-1. A 9 × 9 full-factorial calibration design spanning 0-10 000 pg per mL NT-proBNP and 0-500 pg per mL hs-cTnI was executed across three independently prepared tag lots. Ten spatial spectra were aggregated at the sample level, preprocessed and quantified by a batch-grouped partial least-squares model. Limits of detection were 6.30 pg mL-1 for NT-proBNP and 0.46 pg mL-1 for hs-cTnI; corresponding limits of quantification were 18.7 and 1.35 pg mL-1. Across matrix lots and concentration levels, recoveries were 93.1-107.8% and total coefficients of variation were 4.8-9.4%. Thirty-six independently prepared, blinded artificial-serum specimens representing four dual-biomarker phenotypes were compared with electrochemiluminescence and chemiluminescent microparticle immunoassays. Under an equal-error-variance assumption, Deming slopes were 0.963 and 1.012, concordance correlation coefficients were 0.9951 and 0.9930, and concentration-quadrant agreement was 35/36. Grouped validation and specimen-level comparison assessed the dual readout without treating spatial spectra as independent replicates. This architecture provides a controlled route to simultaneous cardiac-biomarker measurement in artificial serum.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction.ACS sensors · 2026
- Size/Color Dual-Encoded Electrochemiluminescence for Multiplexed Immunoassay of Cardiac Biomarkers.Analytical chemistry · 2026
- T7 Ribonucleic Acid Polymerase-Triggered CRISPR/Cas13a and Branched HCR Cascade Amplification with Machine Learning for SERS Detection of Cardiac Troponin IACS Applied Materials & Interfaces · 2026
- Single-step determination of cardiac troponin molecular form ratios using multiparametric SH-SAW biosensing.Talanta · 2026
- Gemini SERS for Cross-Category Biomarker Detection and Early Warning of Sudden Cardiac Death in Acute Coronary SyndromeACS Nano · 2025
- Label-Free SERS Sensing of Native Aβ with Aptamer-Modified Mesoporous Gold and Gold-Coated Magnetic Nanoparticles Using a Clinical CohortACS Applied Materials & Interfaces · 2025