Real-time tumor tracking for magnetic resonance-guided radiotherapy using label-efficient foundation model adaptation.
Amparo S Betancourt Tarifa, Marcel Verheij, René Monshouwer, John J Hermans, Peter J Koopmans, Erik van der Bijl
Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands. · Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Key points
From the paper's conclusion- MedSAM2 adaptation enabled real-time cine-MRI tumor tracking with limited labels. The single-model approach provided faster inference and simpler deployment, while semi-supervised ensembling showed no significant improvement at higher computational cost.
Abstract
BACKGROUND AND PURPOSE: Real-time tumor tracking on cine magnetic resonance imaging (cine-MRI) enables intra-fraction motion management in magnetic resonance-guided radiotherapy. Pipelines often rely on deformable registration or template matching to propagate contours, which can degrade under non-rigid motion and cine-MRI artifacts. This study evaluated two MedSAM2-based adaptations for real-time tracking with limited labels. MATERIALS AND METHODS: The TrackRAD2025 dataset includes sagittal cine-MRI sequences from six institutions acquired on 0.35 T and 1.5 T MRI-linear accelerators, with 50 labeled and 477 unlabeled training cases and 50 test cases. Tracking was formulated as frame-wise target segmentation from the first-frame ground-truth mask. Method A fine-tuned MedSAM2 on 40 labeled cases and used rank-weighted checkpoint averaging. Method B combined two MedSAM2 models trained on different labeled splits augmented with pseudo-labels, and merged their predictions during inference. RESULTS: On the hidden test set, Method A ranked highest on Dice similarity coefficient (DSC), center distance (CD), 95th-percentile Hausdorff distance (HD95), and mean average surface distance (MASD), with DSC = 0.891, CD = 1.47 mm, HD95 = 4.22 mm, MASD = 1.66 mm, relative dose to 98% of the target volume ( D 98 % ) = 0.936, and runtime of 0.04 s per frame. Method B achieved similar geometric performance and numerically higher relative D 98 % (0.953), at 0.10 s per frame. Paired Wilcoxon signed-rank testing showed no significant differences after correction for multiple testing. CONCLUSIONS: MedSAM2 adaptation enabled real-time cine-MRI tumor tracking with limited labels. The single-model approach provided faster inference and simpler deployment, while semi-supervised ensembling showed no significant improvement at higher computational cost.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Semi-Automated Image Labeling and Object Tracking for MR-Guided Radiotherapy Using a Foundation Vision Model.Journal of imaging informatics in medicine · 2026
- Attention-Guided TransMorph for Real-Time Tumor Tracking in Cine-MRI.Journal of imaging informatics in medicine · 2026
- Glioma Segmentation on Multicenter 2D-Based Magnetic Resonance Imaging Using Low-Rank Adaptation Tuning of a Foundation Model: An External Test Evaluation.Journal of imaging informatics in medicine · 2026
- A novel automatic real-time motion tracking method in MRI-guided radiotherapy using enhanced Tracking-Learning-Detection framework with automatic segmentation.Radiation oncology (London, England) · 2026
- Automated workflow for target volume propagation in online adaptive magnetic resonance guided radiotherapy for lung lesions using foundation models.Physics and imaging in radiation oncology · 2026
- Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)Physics in Medicine & Biology · 2026