Semi-Automated Image Labeling and Object Tracking for MR-Guided Radiotherapy Using a Foundation Vision Model.
Mike Zhu, Jun Hsuang Jen, Daniel E Hyer, Taylor P Trentadue, Timothy L Kline, Bryan J Traughber, Douglas J Moseley
Department of Information Technology, Mayo Clinic, Rochester, MN, USA. zhu.henian@mayo.edu. · Department of Radiation Oncology, University of Iowa, Iowa City, IA, USA.
Key points
From the paper's conclusion- Therefore, leveraging SAM2 to semi-automatically generate labeled training data can substantially reduce the cost of data curation and long-term model maintenance without compromising accuracy.
Abstract
Magnetic resonance-guided radiotherapy (MRgRT) enables real-time tracking of tumor and organ motion for more precise radiation delivery. However, existing clinical tracking software struggles with high-velocity or non-rigid motion. Foundation models, such as Segment Anything Model 2 (SAM2) and MedSAM2, offer robust tracking with fast inference speeds and strong zero-shot accuracy that can improve with fine-tuning. Fine-tuning typically uses expert-labeled datasets, which are expensive to acquire. We explored SAM2's utility in accelerating the labeling process by developing a workflow where novices label < 1% of frames and SAM2 automatically labels the rest. We then evaluated SAM2 and MedSAM2 for tumor tracking on an open-access MRgRT dataset in three configurations: zero-shot, fine-tuned using manually labeled data, and fine-tuned using the semi-automatically labeled data. We measured accuracy with the Dice similarity coefficient, 95th percentile (P95) Hausdorff distance, and centroid distance. MedSAM2 and SAM2 demonstrated strong zero-shot tracking accuracy with no significant difference among the model variants. Fine-tuning significantly improved Dice coefficients (0.874 to 0.891, p = 0.006), P95 Hausdorff distances (9.069 to 4.378 mm, p < 0.001), and centroid distances (5.299 to 1.769 mm, p < 0.001) relative to zero-shot, with no significant difference between using manually labeled and semi-automatically labeled data. Therefore, leveraging SAM2 to semi-automatically generate labeled training data can substantially reduce the cost of data curation and long-term model maintenance without compromising accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time tumor tracking for magnetic resonance-guided radiotherapy using label-efficient foundation model adaptation.Physics and imaging in radiation oncology · 2026
- Segment anything model (SAM)‐driven prompt‐guided interactive delineation of gross tumor volume for rectal cancer neoadjuvant radiotherapyMedical Physics · 2026
- Automated workflow for target volume propagation in online adaptive magnetic resonance guided radiotherapy for lung lesions using foundation models.Physics and imaging in radiation oncology · 2026
- Glioma Segmentation on Multicenter 2D-Based Magnetic Resonance Imaging Using Low-Rank Adaptation Tuning of a Foundation Model: An External Test Evaluation.Journal of imaging informatics in medicine · 2026
- A novel automatic real-time motion tracking method in MRI-guided radiotherapy using enhanced Tracking-Learning-Detection framework with automatic segmentation.Radiation oncology (London, England) · 2026
- Accelerating Volumetric Medical Image Annotation via Short-Long Memory SAM 2IEEE Transactions on Medical Imaging · 2025