Glioma Segmentation on Multicenter 2D-Based Magnetic Resonance Imaging Using Low-Rank Adaptation Tuning of a Foundation Model: An External Test Evaluation.
Chiharu Kai, Masato Nakaya, Satoshi Kasai, Hideaki Tamori, Hirokazu Fujiwara, Tatsuaki Kobayashi, Masahiro Hashimoto, Yohei Kitamura,
Department of Intelligent Information Engineering, Research Promotion Unit, School of Medical Sciences, Fujita Health University, Toyoake City, Aichi, Japan. · Department of Neurosurgery, Tokyo Saiseikai Central Hospital, Minato-Ku, Tokyo, Japan.
Key points
From the paper's conclusion- We used 2D-based fluid-attenuated inversion recovery axial images and conducted parameter optimization based on four-fold cross-validation (189 cases) and external test evaluation (75 cases) using cases collected retrospectively.
Abstract
Research on foundation models is actively progressing. The segment anything model (SAM) and MedSAM are representative foundation models for image segmentation. Recently, low-rank adaptation (LoRA) has been developed, allowing parameter updates without retraining the entire model, thus solving the problem with large data and time required for task-specific fine-tuning. Although many studies have used public databases, few have focused on local data. Moreover, to our knowledge, no studies have fine-tuned MedSAM using LoRA. We aimed to evaluate SAM, MedSAM, and their LoRA-tuned variants (SAM-LoRA and MedSAM-LoRA) using brain magnetic resonance images of gliomas from five centers in Japan and to compare their performance. We used 2D-based fluid-attenuated inversion recovery axial images and conducted parameter optimization based on four-fold cross-validation (189 cases) and external test evaluation (75 cases) using cases collected retrospectively. Dice coefficients, intersection over union (IoU), and the 95% Hausdorff distance (HD95) were used to evaluate the performance of SAM, MedSAM, SAM-LoRA, and MedSAM-LoRA. Additionally, subgroup evaluations were performed according to scanner manufacturer, glioma location, and calcification status. In the external test at the case level using SAM-LoRA and MedSAM-LoRA, the Dice coefficients/IoU/HD95 were 0.9166/0.8506/1.3517 and 0.9051/0.8342/1.8061, respectively. Both SAM-LoRA and MedSAM-LoRA demonstrated significantly higher Dice coefficients and IoU, as well as significantly lower HD95 values, compared with SAM and MedSAM. Subgroup evaluations also showed highly accurate extraction across different scanner manufacturers, glioma locations, and calcification statuses. SAM-LoRA and MedSAM-LoRA achieved high accuracy on an externally evaluated dataset, suggesting potential utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Convergent Performance, Divergent Mechanisms in LoRA-Adapted Vision Foundation Models for Brain MRIarXiv · 2026
- A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3arXiv · 2026
- FedSAM-3D: Adapter-Constrained Federated Adaptation for Transferable Medical Segmentation Foundation Models.IEEE transactions on bio-medical engineering · 2026
- JS10.5.A Data-efficient transfer learning for cross-tumour brain MRI segmentationNeuro-Oncology · 2026
- NeuroRAD-FM: A Distributionally Robust Foundation Model for Precision Neuro-Oncology.Research square · 2026
- Foundation Models for Glioma MRI: A Systematic Scoping Review of Clinical Applications and Translational Readiness.Brain sciences · 2026