Attention-Guided TransMorph for Real-Time Tumor Tracking in Cine-MRI.
Konstantinos Georgas, Theodoros P Vagenas, Ioannis A Vezakis, Ioannis Kakkos, George K Matsopoulos
Biomedical Engineering Lab (BEL), School of Electrical and Computer Engineering, National Technical University of Athens, Athens, 15780, Greece. kostasgeo@biomed.ntua.gr. · Biomedical Engineering Lab (BEL), School of Electrical and Computer Engineering, National Technical University of Athens, Athens, 15780, Greece.
Key points
From the paper's conclusion- A real-time tumor tracking approach for 2D cine-MRI using deep learning-based deformable image registration, based on an improved TransMorph architecture, is presented.
Abstract
Magnetic Resonance Imaging (MRI) is a key modality in cancer treatment, providing high soft tissue contrast for the visualization of tumors and internal anatomy. Radiotherapy, which is widely used in treatments, requires precise tumor segmentation to ensure targeting the true tumor and minimizing radiation exposure to healthy tissues. In this regard, real-time automatic tumor tracking from cine-MRI can provide accurate tumor localization supporting adaptive radiotherapy. Conventional image registration techniques exhibit limitations when handling large misalignments and high computational demands, unlike deep learning methods, with high learning capabilities and fast inference times. A real-time tumor tracking approach for 2D cine-MRI using deep learning-based deformable image registration, based on an improved TransMorph architecture, is presented. The approach adheres to a two-step training paradigm: (1) unsupervised pretraining on unlabeled patient image pairs, and (2) supervised fine-tuning with segmentation labels. Attention gates are integrated into skip connections to enhance spatial selectivity regarding the most relevant regions for alignment. A composite loss function is utilized, synthesizing boundary-weighted Dice, adaptive MSE, L1 and smooth diffusion and edge-based regularization. Both overlap and distance-based metrics were computed to assess the model's segmentation accuracy in the registration of various frames within the patients. The proposed model achieved DSC 93.42 % ± 5 % , 95HD 2.75 ± 3.24 mm, 50HD 0.88 ± 0.40 mm. Extensive benchmarking demonstrated that the proposed framework consistently achieved superior performance compared to the TransMorph model, its variants, and other existing state-of-the-art image registration approaches. Experimental results indicate that this technique may serve as a critical tool for the advancement of MRI-guided radiotherapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time tumor tracking for magnetic resonance-guided radiotherapy using label-efficient foundation model adaptation.Physics and imaging in radiation oncology · 2026
- A multi‐resolution SWIN transformer framework regularized by white matter time‐intensity curve for brain dynamic contrast‐enhanced MR image registrationMedical Physics · 2026
- ACQUISITION TIME-INFORMED BREAST TUMOR SEGMENTATION FROM DYNAMIC CONTRAST-ENHANCED MRI.Proceedings. IEEE International Symposium on Biomedical Imaging · 2026
- The brain tumor sequence registration (BraTS-Reg) challenge for establishing correspondence between pre-operative and follow-up MRI scans of diffuse glioma patientsScientific Reports · 2026
- Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRIarXiv · 2026
- Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration AccuracyarXiv · 2026