Noninvasive Intracranial Pressure Monitoring in Pediatric Traumatic Brain Injury: Systematic Review of Transcranial Doppler and Optic Nerve Sheath Diameter With Identification of an Evidence Gap in Pupillometry.
Maria B Mateo Chavez, Kerly Guevara Maldonado, Andrew Reisner, David Adelson, Andres Rubiano, Jennifer C Muñoz Pareja
Knowledge and Evaluation Research Unit, Mayo Clinic, Rochester, Minnesota. · Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia.
Key points
From the paper's conclusion- TCD and ONSD are feasible adjunctive tools for noninvasive ICP assessment in pediatric TBI, though diagnostic performance varied substantially across studies. Evidence supporting combined modality models remains preliminary. Larger multicenter studies are needed to standardize acquisition protocols, establish age-appropriate thresholds, and define clinical utility.
Abstract
BACKGROUND: To systematically review the diagnostic performance and feasibility of transcranial Doppler (TCD) and optic nerve sheath diameter (ONSD) as noninvasive intracranial pressure (ICP) assessment tools in pediatric traumatic brain injury (TBI). DATA SOURCES: Ovid MEDLINE, EMBASE, Cochrane CENTRAL, and the Cochrane Database of Systematic Reviews were searched from inception through February 2025. STUDY SELECTION: Prospective and retrospective studies evaluating TCD, ONSD, or both against invasive ICP monitoring in children with TBI. DATA EXTRACTION: Two reviewers independently screened studies, extracted data, and assessed risk of bias using Quality Assessment of Diagnostic Accuracy Studies, version 2. Outcomes included ICP correlations and diagnostic accuracy measures (area under the curve [AUC], sensitivity, specificity, and diagnostic thresholds). DATA SYNTHESIS: Six studies met inclusion criteria: three evaluated TCD, two evaluated ONSD, and one evaluated both. TCD findings were variable; pulsatility index (PI) demonstrated the strongest performance, with PI ≥ 1.3 yielding 100% sensitivity and 82% specificity for ICP >20 mmHg in one study, and PI ≥ 1.065 yielding AUC 0.95 and r = 0.68 in another. End-diastolic velocity showed weaker diagnostic performance. ONSD studies were more consistent, with correlations of r = 0.71-0.74, AUC 0.85-0.93, and optimal thresholds of 5.5-6.1 mm. The single combined-modality study reported r = 0.97 and AUC = 0.99 for ONSD plus PI. CONCLUSIONS: TCD and ONSD are feasible adjunctive tools for noninvasive ICP assessment in pediatric TBI, though diagnostic performance varied substantially across studies. Evidence supporting combined modality models remains preliminary. Larger multicenter studies are needed to standardize acquisition protocols, establish age-appropriate thresholds, and define clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Ultrasound and Computed Tomography Optic Nerve Sheath Diameter for Intracranial Pressure Assessment in Pediatric Neurocritical Care.Pediatric neurology · 2026
- Comparison of emergency department-measured optic nerve sheath diameter according to early neurological outcome in pediatric patients with traumatic brain injury.International journal of emergency medicine · 2026
- An Eye on Survival: Association Between Initial Optic Nerve Sheath Diameter and 30-Day Mortality in Patients With Traumatic Brain Injury.Cureus · 2026
- Noninvasive Intracranial Pressure Estimation Using Transcranial Doppler to Rule Out Intracranial Hypertension in Children Undergoing Lumbar Puncture: A Feasibility Study.Pediatric neurology · 2026
- Dynamic Noninvasive Assessment of Intracranial Pressure, Cerebral Perfusion Pressure, and Autoregulation.Journal of neurosurgical anesthesiology · 2026
- Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients.Frontiers in neurology · 2026