Microtensile bond strength and dentin–adhesive interface of universal adhesives before and after artificial aging: an in vitro study
Flor Santander-Rengifo, Carmen Martin Carreras-Presas, César Cayo-Rojas
Peruvian University of Applied Sciences · Universidad Europea de Madrid
Key points
From the paper's conclusion- Therefore, this study evaluated the microtensile bond strength (µTBS) and dentin–adhesive interface of four universal adhesives before and after artificial aging.
Abstract
Universal adhesives (UAs) are widely used for resin composite restorations; however, the durability of the dentin–adhesive interface after aging remains a key clinical concern, as interfacial degradation may compromise bond stability over time. Therefore, this study evaluated the microtensile bond strength (µTBS) and dentin–adhesive interface of four universal adhesives before and after artificial aging. Occlusal thirds of human third molars were sectioned and randomly assigned to four groups: A, Palfique Universal Bond; B, Single Bond Universal; C, All-Bond Universal; D, One Coat 7 Universal. All UAs were used in self-etch mode. Palfique Universal Bond was not light-cured (chemical activation); All-Bond Universal was applied in two coats; the others in one. The total sample comprised 144 sticks. Of these, 120 were tested for µTBS (30/group) at 1 mm/min and subdivided with/without artificial aging (n = 15/subgroup; 10,000 thermocycles between 5 ± 2 °C and 55 ± 2 °C). Failure mode was examined under a stereomicroscope. Adhesive-interface thickness was measured on 24 sticks (n = 6/group) by scanning electron microscopy (SEM). Data were analysed by two-way ANOVA for µTBS, followed by simple comparisons when the interaction was significant. For adhesive-interface thickness, comparisons among adhesives within each aging condition and between aging conditions within each adhesive were evaluated using one-way ANOVA with Scheffé post hoc tests (p < 0.05). Two-way ANOVA showed significant effects of adhesive type, aging condition, and their interaction on µTBS. Group A showed significantly lower µTBS than Groups B–D (all p < 0.001; η2 = 65.9% without aging; η2 = 85.4% with aging); B, C and D did not differ (p > 0.05). Aging reduced µTBS for A and D (p < 0.001 and p = 0.008, respectively) but not for B or C. In the non-aged condition, C and D did not differ (p > 0.05), while D had a thicker interface than A and B (p < 0.05; η2 = 82.5%). After aging, A presented a thinner interface than B–D (p < 0.05; η2 = 93.5%) and was the only UA showing a reduction versus its non-aged counterpart (p = 0.003). Failure modes were predominantly adhesive for A and B, and mainly mixed for C and D (p < 0.001). After artificial aging, Palfique Universal Bond showed lower microtensile bond strength and a thinner adhesive interface, whereas Single Bond Universal and All-Bond Universal maintained comparable bond strength with no reduction in adhesive-interface thickness; One Coat 7 Universal showed a significant decrease in bond strength without a reduction in adhesive-interface thickness. Within the limitations of this in vitro study, the 10-MDP–containing adhesive systems evaluated showed greater interfacial stability after aging than the 3D-SR–containing system tested; however, this finding should be interpreted cautiously because the materials also differed in overall formulation and application protocol.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bond Performance of Four Universal Adhesive Systems on Sound and Biomimetically Remineralized Artificially Caries-Affected Dentin Before and After Artificial AgingAdhesives · 2026
- Effect of short dentin etching and water storage on bonding of resin composite to dentin with universal and two-step self-etch adhesive systemsScientific Reports · 2025
- Comparative assessment of the resin-dentin interface using three different universal adhesives: An ex vivo studyJournal of Conservative Dentistry and Endodontics · 2026
- Effect of Silane Incorporation on the Bonding Performance of Universal Adhesives to Dentin.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- Bond strength performance of a self-curing bulk-fill restorative system and light-cured restorative systems after aging: an in vitro study.Odontology · 2026
- Core Buildup Composite Resins Bond Strength to Dentin and Microhardness Using Universal Adhesives.Journal of functional biomaterials · 2026