An inversion-forward method for γ-ray spectrum background subtraction based on the ML-EM inversion algorithm.
Wei Chen, Xuemei Wang, Wenbiao Liu, Lihao Wang, Zhihui Wang
Northwest Institute of Nuclear Technology, Xi'an, 710024, China. Electronic address: chwei2601@163.com. · Northwest Institute of Nuclear Technology, Xi'an, 710024, China.
Key points
From the paper's conclusion- To address the limitation of traditional methods in accurately subtracting backgrounds from complex γ-ray spectra, particularly those containing overlapping peaks, this paper proposes an inversion-forward method for γ-ray spectrum background subtraction based on the Maximum Likelihood-Expectation Maximization (ML-EM) inversion algorithm.
Abstract
γ-ray spectrum analysis is one of the widely used techniques in the field of nuclear radiation detection. Background subtraction from γ-ray spectra can improve the quantitative accuracy of γ-emitting radionuclides. To address the limitation of traditional methods in accurately subtracting backgrounds from complex γ-ray spectra, particularly those containing overlapping peaks, this paper proposes an inversion-forward method for γ-ray spectrum background subtraction based on the Maximum Likelihood-Expectation Maximization (ML-EM) inversion algorithm. A 4″ × 4″×16″ thallium-doped sodium iodide (NaI(Tl)) detector was used to acquire γ-ray spectra containing information from 241Am, 137Cs, 60Co, 152Eu, 133Ba, and 22Na. Focusing on 241Am, 137Cs, and 60Co while treating the other nuclides as interference sources, the proposed method was applied for background subtraction. The results were compared with those obtained using the Maestro32 software and the Statistics-sensitive Nonlinear Iterative Peak-clipping (SNIP) method. The results demonstrate that the background subtraction accuracy of the proposed method is significantly superior to the other two methods. After background subtraction, the maximum absolute deviation of the calculated activities of 241Am, 137Cs, and 60Co (where the 241Am characteristic peak overlaps with that of 133Ba, and the 60Co characteristic peaks overlap with those of 152Eu, 133Ba, and 22Na) from the reference values is only 5.6%, compared to 48.8% for Maestro32 and 72.5% for the SNIP method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Applicability and parameter optimization of the SASNIP algorithm for background subtraction of gamma spectra measured with NaI(Tl) detectors.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Gamma-ray spectrum unfolding and air-absorbed dose-rate estimation using a two-stage spectral learning framework.Radiation protection dosimetry · 2026
- Quantitative mobile gamma-ray spectrometry through Bayesian inferenceNature Communications · 2026
- Site-specific field comparison of in situ NaI(Tl) gamma-ray spectrometry for ambient dose equivalent rate estimation and 137Cs spectral screening.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Preclinical application and evaluation of an energy-based spectral unmixing method for multi-radionuclide SPECT.Physics in medicine and biology · 2026
- Variability and bias in the calculation of iodine uptake with an adaptive background subtraction method in contrast-enhanced mammography.Physics in medicine and biology · 2026