Preclinical application and evaluation of an energy-based spectral unmixing method for multi-radionuclide SPECT.
Matthew Strugari, Sam Porter, Kris Thielemans, Kimberly D Brewer
IWK Health Centre, 5850/5980 University Avenue, Halifax, Nova Scotia, B3K 6R8, Canada. · Institute of Nuclear Medicine, University College London, 235 Euston Road, London, England, NW1 2BU, United Kingdom of Great Britain and Northern Ireland.
Key points
From the paper's conclusion- Across all cases, spectral unmixing also demonstrated superior contrast and reduced noise compared to TEW.Significance.This energy-based spectral unmixing approach provides enhanced crosstalk correction, quantitative accuracy, and image quality compared to conventional methods, facilitating flexible application in diverse SPECT systems and radionuclide combinations.
Abstract
Objective.Crosstalk poses significant challenges in multi-radionuclide SPECT, where γ-rays from one radionuclide are incorrectly attributed to a different radionuclide, compromising image fidelity and interpretations. Although the triple energy window (TEW) method is widely accepted for correcting crosstalk in the acquired energy spectrum, its effectiveness depends on the gamma camera's energy resolution and statistical counts on a pixel-by-pixel basis. Furthermore, subtractive corrections applied before image reconstruction, such as TEW, alter the Poisson distribution of detected events, negatively impacting statistical reconstruction accuracy, reconstructed image noise, and image quality. To address these challenges, we introduce an energy-based spectral unmixing crosstalk correction approach in a preclinical setting using the open-source Synergistic Image Reconstruction Framework (SIRF) and Core Imaging Library (CIL). This method employs a mixing matrix to decompose hyperspectral data into distinct radionuclide distributions during synergistic reconstruction. Approach.Data were acquired with the Cubresa Spark preclinical SPECT scanner using99mTc/123I in measurement and simulation, and99mTc/111In in simulation. A mouse-sized phantom study employed five 4 MBq line sources with linearly varying mixtures of radioactivity. The images were reconstructed using primary energy windows, TEW, spectral unmixing, and gold standard simulation data representing activity distributions free of crosstalk. Performance evaluation used root-mean-square error (RMSE) for activity quantitation and image contrast, while noise was assessed separately in each image.Main results.In the99mTc/123I measurement, primary energy windows yielded a mean quantitation RMSE of 0.49, with improvements of 32% observed with TEW and 74% with spectral unmixing. Simulation results were consistent, giving an RMSE of 0.44 for primary energy windows, with improvements of 51%, 83%, and 95% observed with TEW, spectral unmixing, and gold standard methods. For the99mTc/111In simulation, the mean quantitation RMSE was 0.15 with primary energy windows, while TEW, spectral unmixing, and gold standard methods improved accuracy by 57%, 57%, and 84%, respectively. Across all cases, spectral unmixing also demonstrated superior contrast and reduced noise compared to TEW.Significance.This energy-based spectral unmixing approach provides enhanced crosstalk correction, quantitative accuracy, and image quality compared to conventional methods, facilitating flexible application in diverse SPECT systems and radionuclide combinations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radionuclide Dependence of Distance-Dependent Spatial Resolution and Resolution Recovery in SPECT: A SIMIND Monte Carlo Simulation Study.Biomedical physics & engineering express · 2026
- Simulation-embedded MLEM reconstruction using SIMIND for quantitative myocardial SPECT.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Integration of Spectral CT with PET and SPECT: Bringing Tissue Composition Information to Molecular Imaging.ArXiv · 2026
- Quantitative Comparison of SPECT and PET Performance for Clinical Theranostic ApplicationsJournal of Nuclear Medicine · 2025
- Tensor-Driven Spectral CT Reconstruction via Noise-Adaptive Channel Weighting and Deterministic Block Matching.IEEE access : practical innovations, open solutions · 2026
- Dimensionality reduction for partial-volume correction in quantitative SPECT.Physics in medicine and biology · 2026