Gamma-ray spectrum unfolding and air-absorbed dose-rate estimation using a two-stage spectral learning framework.
Jinfeng Bai, Yang Lu, Suyalatu Zhang, Xiaolei Ma, Yongshun Huang, Haochun Yu, Dexin Wang, Jianfang Zhang,
College of Computer Science and Technology, Inner Mongolia Minzu University, No. 996 West Xilamulun Street, Horqin District, Tongliao 028000, Inner Mongolia, China. · Inner Mongolia Joint Laboratory of Nuclear and Radiation Detection, No. 996 West Xilamulun Street, Horqin District, Tongliao 028000, Inner Mongolia, China.
Key points
From the paper's conclusion- The results support a sequential pathway from detector spectra to reconstructed incident spectra and subsequent dose-rate estimates under the investigated conditions.
Abstract
Gamma-ray spectrum unfolding and air-absorbed dose-rate estimation are important for environmental radiation monitoring. This study presents a sequential spectral analysis strategy linking incident-spectrum reconstruction with model-based dose-rate estimation. A LaBr$_{3}$:Ce response matrix was constructed from 591 monoenergetic Geant4 spectra, and 4000 mixed spectra were generated for supervised learning. Across three repeated runs, the unfolding model achieved a mean absolute error of $0.021732 \pm 0.001035$ and an $R^{2}$ of $0.932326 \pm 0.004621$. Using the reconstructed incident-spectrum weights as inputs, the direct tri-branch dose-regression model achieved an $R^{2}$ of $0.99335 \pm 0.00456$ and a mean absolute percentage error of $1.780\% \pm 0.620\%$. Application to a measured soil gamma-ray spectrum demonstrated the applicability of the unfolding model under a complex environmental condition. The results support a sequential pathway from detector spectra to reconstructed incident spectra and subsequent dose-rate estimates under the investigated conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Site-specific field comparison of in situ NaI(Tl) gamma-ray spectrometry for ambient dose equivalent rate estimation and 137Cs spectral screening.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Development of Background Model for a Shielded HPGe DetectorPure and Applied Geophysics · 2026
- Segmented G(E) Function Compensation Method for Gamma Dose Rate Meters Considering Asymmetric Error Distribution Across Energy RegionsSymmetry · 2026
- Identification of alpha-emitting radionuclides in ambient measurements using unfolding method based on iterative and maximum likelihood algorithms.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Quantitative mobile gamma-ray spectrometry through Bayesian inferenceNature Communications · 2026
- Machine learning classification for irradiated material gamma ray spectraJournal of Radioanalytical and Nuclear Chemistry · 2026