Effect of transducer scanning velocity during extended field of view imaging acquisition on pennate and fusiform muscles echo intensity.
Paulo Ricardo De David Evangelho, Bruno Turcatti-Mendez, Martina Weis Regert, Heinrich Leon Souza Viera, Marco Aurélio Vaz, Fábio Juner Lanferdini
Biomechanics Laboratory, Physical Education and Sports Center, Universidade Federal de Santa Maria, Roraima Avenue, 1000, Camobi, Santa Maria, Rio Grande do Sul, 97105-900, Brazil. · Exercise Research Laboratory, School of Physical Education, Physiotherapy and Dance, Universidade Federal do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.
Key points
From the paper's conclusion- Transducer scanning velocity affects EI measurements in TA compartments, particularly under slow conditions, although these differences may not represent true physiological changes. In contrast, BB and VL measurements were unaffected, and all velocities demonstrated excellent interrater reliability.
Abstract
PURPOSE: This study investigated the effects of transducer scanning velocity on echo intensity (EI) of muscles with different architectures [biceps brachii (BB), vastus lateralis (VL), and tibialis anterior (TA)] and determined interrater reliability across velocities. METHODS: Ideal transducer velocity for each muscle was determined by the ultrasound system and measured using reflective markers and video analysis. Fast and slow velocities were set at ±50% of the ideal velocity (i.e., control condition). Three images per velocity were collected in 40 participants, with speed controlled by a digital metronome. EI, adipose, and superficial tissue thicknesses were analyzed by two blinded raters using ImageJ®. Repeated-measures ANOVA with Tukey post hoc test were applied for absolute and percentage values. Reliability was assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), and minimum detectable change (MDC). RESULTS: Interrater reliability was excellent for all muscles and velocities (r ≥ 0.933). Significant differences were observed only in TA. Slow velocity produced higher EI in TA's superior compartment compared with control and fast conditions (5% and 6%, respectively), and higher EI in the inferior compartment compared with fast velocity (4%). However, all differences were within the SEM and below the MDC. No significant differences were observed in BB or VL. CONCLUSION: Transducer scanning velocity affects EI measurements in TA compartments, particularly under slow conditions, although these differences may not represent true physiological changes. In contrast, BB and VL measurements were unaffected, and all velocities demonstrated excellent interrater reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound-derived muscle thickness and muscle quality parameters vary across regions of the vastus lateralis in physically active and endurance-trained men.Journal of ultrasound · 2026
- Effects of operator experience and measurement depth on skeletal muscle shear wave elastography.Journal of ultrasound · 2026
- Muscle activation assessment using ultrasound time-harmonic elastography and tonic vibration reflexJournal of Biomechanics · 2026
- MuscleExpert: a semi-automated tool delivering ImageJ-comparable measurements of muscle thickness, area, and quality.PeerJ · 2026
- Shear-Wave Anisotropy of the Vastus Lateralis During Low-Level Isometric Contraction Measured with Ultrasound Time-Harmonic Elastography.Annals of biomedical engineering · 2026
- Effects of region of interest size and measurement location on ultrasound-derived hamstrings muscle quality indices in children.Ultrasound (Leeds, England) · 2026