Annals of biomedical engineering

Shear-Wave Anisotropy of the Vastus Lateralis During Low-Level Isometric Contraction Measured with Ultrasound Time-Harmonic Elastography.

Tom Meyer, Stefan Klemmer Chandía, Pascal Engl, Giacomo Valli, Yanglei Wu, Klaus Jenderka, Thomas Bartels, René Schwesig,

Department of Radiology, Charité - Universitätsmedizin Berlin, 10117, Berlin, Germany. · Department of Engineering and Natural Sciences, University of Applied Sciences Merseburg, 06217, Merseburg, Germany.

Key points

From the paper's conclusion
  • VL exhibited marked shear-wave anisotropy at rest that increased with low-level contraction intensities, indicating disproportionate stiffening along the fiber direction. THE provides a rapid, cost-effective, orientation-sensitive readout of muscle mechanics that may support studies of neuromuscular function and pathology.

Abstract

PURPOSE: Skeletal muscle is commonly modeled as a transversely isotropic medium; however, the behavior of its anisotropy under active loading remains insufficiently characterized. In this study, we used ultrasound time-harmonic elastography (THE) to quantify direction-dependent shear-wave speed (SWS) in the vastus lateralis (VL) muscle at rest and during low isometric contraction intensities. METHODS: Twenty-six healthy adults (15 men, 11 women; 25.0 ± 4.1 y) underwent multi-frequency THE (60-80 Hz). The transducer was aligned parallel (longitudinal) and perpendicular (transverse) to VL fascicles, and measurements were acquired at rest and at 15% and 30% of maximal voluntary contraction (MVC). Fractional anisotropy (FA) was computed from S W S ‖ and S W S ⊥ , yielding zero for isotropic media. Orientation and contraction effects were tested with repeated-measures analyses. RESULTS: At rest, longitudinal SWS exceeded transverse SWS ( 2.5 ± 0.2 vs. 1.4 ± 0.1 m/s; paired t-test p < 0.01 ). With contraction, SWS increased to 3.2 ± 0.2 and 3.8 ± 0.3 m/s (15%, 30% MVC) along fibers, and to 1.6 ± 0.1 and 1.8 ± 0.1 m/s across fibers (all p < 0.01 ). A two-factor repeated-measures ANOVA on SWS showed main effects of orientation and contraction and a significant interaction (all p < 0.01 ). FA increased from 0.37 ± 0.04 at rest to 0.43 ± 0.04 at 15% and 0.47 ± 0.03 at 30% MVC ( p < 0.01 ). No sex- or BMI-related effects were detected. CONCLUSION: VL exhibited marked shear-wave anisotropy at rest that increased with low-level contraction intensities, indicating disproportionate stiffening along the fiber direction. THE provides a rapid, cost-effective, orientation-sensitive readout of muscle mechanics that may support studies of neuromuscular function and pathology.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Shear-Wave Anisotropy of the Vastus Lateralis During Low-Level Isometric Contraction Measured with Ultrasound Time-Harmonic Elastography — Science Skim