Ultrasound-derived muscle thickness and muscle quality parameters vary across regions of the vastus lateralis in physically active and endurance-trained men.
Giuseppe Rosaci, Morgana Lunardi, Sandro Bartolomei, Raphael Luiz Sakugawa, Fernando Diefenthaeler
Department for Life Quality Studies, University of Bologna, Bologna, Italy. · Biomechanics Laboratory, Federal University of Santa Catarina, Florianópolis, Brazil.
Key points
From the paper's conclusion- All parameters may vary along the VL muscle belly. Ultrasound-derived assessments of muscle architecture and quality based on a single measurement site/region should be interpreted with caution.
Abstract
PURPOSE: This study primarily investigated differences in muscle thickness (MT), corrected echo intensity (cEI), subcutaneous fat thickness (SFT) and predicted fat fraction (FF%) across regions/sites of the vastus lateralis (VL) muscle. A secondary exploratory aim was to compare these parameters between endurance-trained and physically active men groups. METHODS: Measurements were obtained from four groups of men (physically active individuals, cyclists, runners, and triathletes; n = 26; 29.2 ± 8.4 y, 75.3 ± 12.3 kg, 176.8 ± 8.3 cm). Panoramic B-mode ultrasound was used to assess cEI and FF% at 0-25%, 25-50%, 50-75% and 75-100% of the muscle length. MT and SFT were assessed at the midpoints of each region (12.5%, 37.5%, 62.5%, and 87.5%). One-way repeated-measures ANOVA compared regions and sites with pooled groups, while one-way ANOVA compared groups. RESULTS: cEI was significantly lower in the middle (25-75%) than in both the distal (0-25%) and proximal (75-100%) regions (p ≤ 0.002, g = 0.61-0.79). FF% was higher in the proximal region than in all other regions (p ≤ 0.025, g = 0.61-0.92), and higher at 25-50% than 0-25% (p = 0.011, g = 0.31). SFT was greater at 87.5% than at all other sites (p < 0.001, g = 1.97-2.45), while MT was higher at 37.5% and 62.5% than at 12.5% and 87.5% (p < 0.001, g = 0.94-2.60). Exploratory group comparisons showed no significant differences in any parameter (p > 0.05). CONCLUSION: All parameters may vary along the VL muscle belly. Ultrasound-derived assessments of muscle architecture and quality based on a single measurement site/region should be interpreted with caution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of transducer scanning velocity during extended field of view imaging acquisition on pennate and fusiform muscles echo intensity.Journal of ultrasound · 2026
- Effects of region of interest size and measurement location on ultrasound-derived hamstrings muscle quality indices in children.Ultrasound (Leeds, England) · 2026
- Normative Reference Values and Cut-Off Points for Nutritional Ultrasound: The VALORES Study.Journal of cachexia, sarcopenia and muscle · 2026
- Investigation of age- and sex-specific reference values for lower-limb muscle thickness using ultrasonography.Journal of rural medicine : JRM · 2026
- Automatic Multiparametric Quantitative Ultrasound Framework for Segmentation and Characterization of Layered Soft Tissues.Ultrasound in medicine & biology · 2026
- The Effect of Hydration Status and Carbohydrate Restriction on Ultrasound-Derived Muscle Imaging Variables.Journal of functional morphology and kinesiology · 2026