MuscleExpert: a semi-automated tool delivering ImageJ-comparable measurements of muscle thickness, area, and quality.
Zongpan Li, Li-Qun Zhang, Marcel Bahia Lanza
Physical Therapy and Rehabilitation Sciences, University of Maryland Baltimore, Baltimore, MD, United States of America.
Key points
From the paper's conclusion- The TOST for MT, CSA, and MQ were within their respective equivalence margins. The ICC was excellent for all measures (MT: ICC = 0.999; CSA: ICC = 0.999; MQ: ICC = 1.000). Precision was similarly high, with CVs of 0.49% (MT), 0.54% (CSA), and 0.33% (MQ), demonstrating minimal variability between the two methods. SEM values were low across all outcomes, corresponding to 0.49% (MT), 0.53% (CSA), and 0.23% (MQ). Finally, the Bland-Altman analysis demonstrated minimal systematic differences and no proportional bias between ImageJ and MuscleExpert for all metrics. The present findings indicate that MuscleExpert and ImageJ produce nearly identical results for MT, CSA, and MQ. These findings support the integration of MuscleExpert into clinical and research workflows, offering a more efficient solution for muscle assessment without compromising measurement integrity.
Abstract
BACKGROUND: Most image-analysis software programs were not designed specifically for ultrasound-based measurements, resulting in irrelevant general-purpose features that force users to navigate through multiple menus and making the analysis time-consuming and increasing the likelihood of error. The aim of this study was to present and validate the semi-automated MuscleExpert software against the widely used ImageJ by comparing muscle thickness (MT), cross-sectional area (CSA), and muscle quality (MQ-measured as echo intensity). METHODS: Ten volunteers (five males; age: 44.9 ± 23.5 years) participated in this cross-sectional study. Ultrasound images of the tibialis anterior and medial gastrocnemius muscles were acquired using 2D B-mode ultrasonography and analyzed in both software programs. Equivalence of means was evaluated via the two-one-sided tests (TOST) procedure; the reliability between means was quantified by an intraclass correlation coefficient (ICC); the precision was expressed as the coefficient of variation (CV) and standard error of measurement (SEM); and agreement was assessed using Bland-Altman plots. RESULTS: The TOST for MT, CSA, and MQ were within their respective equivalence margins. The ICC was excellent for all measures (MT: ICC = 0.999; CSA: ICC = 0.999; MQ: ICC = 1.000). Precision was similarly high, with CVs of 0.49% (MT), 0.54% (CSA), and 0.33% (MQ), demonstrating minimal variability between the two methods. SEM values were low across all outcomes, corresponding to 0.49% (MT), 0.53% (CSA), and 0.23% (MQ). Finally, the Bland-Altman analysis demonstrated minimal systematic differences and no proportional bias between ImageJ and MuscleExpert for all metrics. The present findings indicate that MuscleExpert and ImageJ produce nearly identical results for MT, CSA, and MQ. These findings support the integration of MuscleExpert into clinical and research workflows, offering a more efficient solution for muscle assessment without compromising measurement integrity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability and criterion validity of abductor hallucis muscle volume measurements using ultrasound and MRI by assessors with limited image analysis experience.PloS one · 2026
- Effect of transducer scanning velocity during extended field of view imaging acquisition on pennate and fusiform muscles echo intensity.Journal of ultrasound · 2026
- Effects of region of interest size and measurement location on ultrasound-derived hamstrings muscle quality indices in children.Ultrasound (Leeds, England) · 2026
- Muscle ultrasound for nutrition assessment: Practical clinical protocols.Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition · 2026
- Automatic Multiparametric Quantitative Ultrasound Framework for Segmentation and Characterization of Layered Soft Tissues.Ultrasound in medicine & biology · 2026
- Multidimensional Quality Evaluation of Imaging Performance for Musculoskeletal Ultrasound Computed Tomography System.Bioengineering (Basel, Switzerland) · 2026