Monte Carlo-based three-dimensional dose evaluation for rotational cerebral angiography: peak dose to brain and skin and Dose-Volume Histogram (DVH) analysis of the brain.
Hitoshi Miyazaki, Toshioh Fujibuchi, Donghee Han, Koji Oura, Hiroshi Hamasaki, Hideki Yoshikawa, Koichi Arimura, Toyoyuki Kato,
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1- 1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. miyazaki.hitoshi.036@m.kyushu-u.ac.jp. · Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812- 8582, Japan.
Key points
From the paper's conclusion- PHITS-based three-dimensional dose evaluation allowed localized high-dose regions in the brain and skin to be visualized and quantified. DVH analysis complemented the peak dose assessment by providing volumetric information on the brain-dose distribution.
Abstract
BACKGROUND AND PURPOSE: Rotational cerebral angiography produces complex, nonuniform dose distributions; the mean brain dose may not sufficiently represent localized high-dose regions. This study aimed to visualize three-dimensional dose distributions in the brain and skin using PHITS, estimate peak brain dose (PBD) and peak skin dose (PSD), and evaluate the brain dose distribution using dose-volume histogram (DVH) analysis. MATERIALS AND METHODS: X-ray spectra for 3D digital subtraction angiography (3D-DSA, 70 kV) and cone-beam computed tomography (CBCT, 109 kV) were generated using SpekPy and implemented in PHITS. A rotational irradiation model covering approximately 200° was constructed using a multisource approach based on projection-dependent tube current-time product values. The model was validated using a PMMA phantom. Three-dimensional dose distributions were calculated using the adult male mesh-type reference computational phantom; PBD, PSD, and brain DVH indices were evaluated. RESULTS: Calculated doses agreed with measured values within 5.2%. Dose concentrations were mainly observed in the occipital region. The PBD and PSD were 25.1 and 44.1 mGy for 3D-DSA and 101.3 and 139.1 mGy for CBCT, respectively. The PBD was 3.3 times higher than the mean brain dose for 3D-DSA and 2.3 times higher for CBCT. DVH analysis showed that CBCT shifted the brain-dose distribution toward higher-dose regions, with D10% values of 14.9 and 70.0 mGy for 3D-DSA and CBCT, respectively. CONCLUSIONS: PHITS-based three-dimensional dose evaluation allowed localized high-dose regions in the brain and skin to be visualized and quantified. DVH analysis complemented the peak dose assessment by providing volumetric information on the brain-dose distribution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Identifying High-Dose Views and Modes in the Catheterization Laboratory: A Run-Level Mixed-Effects Analysis.Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2026
- Patient radiation dose in diagnostic cerebral angiography for intracranial aneurysm: local diagnostic reference levels from a single-center study in Thailand.Radiation protection dosimetry · 2026
- Toward Indication-Stratified Local Reference Levels for IGRT Cone-Beam CT: A Clinical Audit of CTDIvol and DLP Across Ten Workflows on Versa HD.Health physics · 2026
- Angio-CT does not increase patient radiation exposure compared to conventional cone-beam CT for intra-arterial liver procedures.European radiology · 2026
- Effective Dose Evaluation of Cerebral Angiography Using Kerma Area Product and Development of Effective Dose Conversion Factors.Diagnostics (Basel, Switzerland) · 2026
- PHITS-based validation of occupational doses during coronary angiography procedures.Radiological physics and technology · 2026