Angio-CT does not increase patient radiation exposure compared to conventional cone-beam CT for intra-arterial liver procedures.
Charlotte Schneider, Han Keijzers, Erik Jan Rijkhorst, Kenneth Hergaarden, Tarik Baetens, Regina Beets-Tan, Belinda de Wit-van der Veen, Elisabeth Klompenhouwer
Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands. · Department of Medical Physics and Technology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
Key points
From the paper's conclusion- Hybrid angiography suites incorporating angio-CT significantly reduced 3D effective dose compared to single-phase CBCT imaging. However, the total effective dose did not remain significant after uncertainty correction. Therefore, the use of angiography suites incorporating dual-phase angio-CT does not appear to change patient radiation exposure during intra-arterial liver procedures.
Abstract
OBJECTIVES: To evaluate patient radiation dose during intra-arterial liver procedures using Computed Tomography angiography (angio-CT) compared with C-arm Cone-Beam CT (CBCT). MATERIAL AND METHODS: This retrospective study included bland embolization and radioembolization mapping procedures performed between November 2021 and December 2024 using dual-phase angio-CT or single-phase CBCT on a hybrid angiography suite. Effective dose was calculated by converting dose-area and dose-length product using conversion factors. Fluoroscopy-only (2D), CBCT/angio-CT (3D) effective dose and total effective dose were compared using the Mann-Whitney U-test. Bootstrap resampling and permutation testing with Monte Carlo error propagation were applied to assess the robustness of 3D and total effective dose comparisons. RESULTS: Ninety-two procedures were included: 48 in the CBCT group and 44 in the angio-CT group. The 2D effective dose was comparable. The 3D effective dose was 4.1-fold lower in the angio-CT group (median 9.85 [IQR: 5.37-22.6 mSv] vs 39.9 mSv [IQR: 21.2-69.6 mSv], p < 0.001), resulting in 1.6-fold reduction in total effective dose for procedures performed by angio-CT (median 34.6 [IQR: 23.7-54.3 mSv] vs 55.9 mSv [IQR: 37.6-103 mSv], p < 0.001). After dose conversion uncertainty correction, corrected p-values were < 0.001 for 3D effective dose and 0.053 for the total dose. CONCLUSION: Hybrid angiography suites incorporating angio-CT significantly reduced 3D effective dose compared to single-phase CBCT imaging. However, the total effective dose did not remain significant after uncertainty correction. Therefore, the use of angiography suites incorporating dual-phase angio-CT does not appear to change patient radiation exposure during intra-arterial liver procedures. KEY POINTS: Question What is the effect of integrating angio-CT into hybrid angiography suites on patient radiation exposure? Findings Dual-phase angio-CT integration into intra-arterial liver therapy workflows does not increase overall procedural radiation exposure and is associated with a decreased 3D effective dose. Clinical relevance Angio-CT offers several clinical advantages, and existing literature demonstrates improved image quality compared with CBCT. This study shows that dual-phase angio-CT does not increase patient radiation exposure compared to single-phase CBCT, supporting its use when available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effective Dose Evaluation of Cerebral Angiography Using Kerma Area Product and Development of Effective Dose Conversion Factors.Diagnostics (Basel, Switzerland) · 2026
- CBCT Dose Is Reduced with Angular Tube Current Modulation While Maintaining Image Quality and Reducing Photon Starvation Artifacts.Annals of biomedical engineering · 2026
- Ultra-Low-Dose Noise-Free Technology to Reduce Radiation Exposure During Coronary AngiographyCirculation Cardiovascular Interventions · 2026
- Identifying High-Dose Views and Modes in the Catheterization Laboratory: A Run-Level Mixed-Effects Analysis.Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2026
- Monte Carlo-based three-dimensional dose evaluation for rotational cerebral angiography: peak dose to brain and skin and Dose-Volume Histogram (DVH) analysis of the brain.Radiological physics and technology · 2026
- Intraoperative cone-beam CT for real-time quality control in CSF shunt surgery: a prospective workflow study.Brain & spine · 2026