PHITS-based validation of occupational doses during coronary angiography procedures.

Marianna Lourdes Marie L Grande, Ranzivelle Marianne Roxas-Villanueva

Department of Science and Technology-Philippine Nuclear Research Institute, Commonwealth Avenue, Diliman, Quezon City, Philippines. annamariegrande@gmail.com. · Institute of Physics, University of the Philippines Los Baños, Laguna, Philippines.

Computational

Key points

From the paper's conclusion
  • These findings validate the PHITS model as a reliable dosimetric tool under the simulated conditions and demonstrate the influence of gantry angulation on scatter field geometry.

Abstract

Occupational radiation monitoring in interventional cardiology remains inconsistent in many resource-limited settings, where personal dosimetry programs are incomplete or absent. This study employed the Particle and Heavy Ion Transport code System (PHITS) to estimate occupational radiation doses to medical staff across nine standard projection angulations during diagnostic coronary angiography. The simulation modeled a point x-ray source at 65 kVp with a water phantom representing the patient, and used T-point tallies to compute ambient dose equivalent H*(10) at staff positions corresponding to the cardiologist, fellow, radiation technologist, and nurse. Results show the cardiologist consistently received the highest dose across all projections, with the AP/AP and LAO10/CRAN30 angulations producing peak values and RAO15/CRAN45 the lowest. The cumulative per-procedure cardiologist dose falls within the range reported in published international literature and agrees to within approximately 10% of a locally established Philippine benchmark. A pronounced dose gradient was observed across staff roles, with the cardiologist receiving substantially higher exposure than other personnel. These findings validate the PHITS model as a reliable dosimetric tool under the simulated conditions and demonstrate the influence of gantry angulation on scatter field geometry. The study supports the use of Monte Carlo-based computational dosimetry as a practical alternative for occupational dose assessment in settings lacking consistent personal monitoring, with direct implications for radiation protection planning in Philippine catheterization laboratories.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

PHITS-based validation of occupational doses during coronary angiography procedures — Science Skim