Radiation protection dosimetry

From whole-body dosimetry to local dose assessment: a 3-y experience in interventional practice.

Silvano Filice

Medical Physics Unit, Azienda Ospedaliero-Universitaria of Parma, via Gramsci 14, 43126, Parma, Italy.

Key points

From the paper's conclusion
  • Empirically derived conversion coefficients provide a valuable complementary approach for the retrospective estimation of localized dose exposure when dedicated dosimetry is unavailable.

Abstract

This 3-y retrospective study analyzed 180 paired dosimetry records from five interventional radiologists and five cardiologists, comparing whole-body Hp(10) with eye-lens Hp(3) and extremity Hp(0.07) doses. Moderate-to-strong linear correlations were observed (r = 0.86-0.91, R2 = 0.73-0.83), indicating that chest-level dosemeters may support the estimation of localized exposure. Coefficients of variation were ~30% for k1 and 27% for k2, reflecting heterogeneous exposure conditions. Variance-component analysis showed that inter-operator variability accounted for 20%-25% of total variance, versus 75%-80% residual within-operator variability, likely reflecting differences in workload, case mix, positioning, exposure geometry, shielding, and measurement uncertainty. The eye-lens conversion coefficient was higher in cardiologists (1.8) than in the non-neurointerventional radiology/neurointerventional radiology group (0.68), suggesting that operator-group-specific conversion coefficients may be more appropriate than a single universal coefficient. Empirically derived conversion coefficients provide a valuable complementary approach for the retrospective estimation of localized dose exposure when dedicated dosimetry is unavailable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

From whole-body dosimetry to local dose assessment: a 3-y experience in interventional practice — Science Skim