Diagnostic performance of liver virtual non-contrast and virtual unenhanced reconstructions derived from photon-counting detector CT of the upper abdomen.
Chiara Gnasso, Gloria Marras, Giulia Piccinni, Davide Serra, Enrico Camisassa, Davide Vignale, Antonio Esposito, Anna Palmisano
Vita-Salute San Raffaele University, Milan, Italy. · IRCCS Ospedale San Raffaele, Milan, Italy.
Key points
From the paper's conclusion- VUE reconstructions showed good agreement with TNC attenuation in the liver and spleen in both contrast phases, whereas LVNC systematically underestimated attenuation in iodine-enhancing organs and was closer to TNC than VUE only in subcutaneous fat and venous-phase muscle. Substantial bias in vascular and bone structures limits the interchangeability of both algorithms with TNC imaging. VNC may support a potential reduction in radiation dose when replacing a planned TNC acquisition; since lesion detection and characterization were not evaluated, the safe omission of TNC was not demonstrated.
Abstract
BACKGROUND: Photon-counting detector computed tomography (PCD-CT) enables native spectral imaging with the generation of virtual non-contrast (VNC) images from contrast-enhanced acquisitions. Two reconstruction algorithms are currently available, Virtual Unenhanced (VUE) and Liver Virtual Non-Contrast (LVNC), but their reliability compared with True Non-Contrast (TNC) imaging in abdominal applications remains incompletely established. This study evaluated the quantitative accuracy, image quality, and potential clinical impact of VNC reconstructions derived from PCD-CT. METHODS: In this retrospective single-center study, 150 patients, of whom 140 were included for the analyses, underwent multiphasic PCD-CT including TNC, arterial, and portal venous phases. VNC datasets were generated from arterial and venous acquisitions using the VUE and LVNC algorithms. Tissue attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared with TNC images. The agreement of VNC reconstructions with TNC-based classification criteria for hepatic steatosis, myosteatosis, and osteoporosis was also evaluated. RESULTS: Significant attenuation differences were observed between TNC and VNC reconstructions across most tissues. The smallest errors were found in soft tissues, particularly the liver and spleen, whereas the largest discrepancies occurred in vascular and osseous structures. SNR was higher on VNC than on TNC images in the liver, spleen and paravertebral muscle but lower in several other tissues, whereas CNR was higher with LVNCa and lower with VUEv than with TNC. VUE most closely reproduced TNC attenuation in the liver and spleen, whereas LVNC systematically underestimated attenuation in iodine-enhancing organs. Agreement with TNC-based criteria for hepatic steatosis, myosteatosis and osteoporosis required reconstruction-specific cut-offs, which should be considered exploratory. Omitting TNC could potentially reduce radiation exposure by 16.5% for upper abdomen and 21.2% for total abdominal examinations. CONCLUSIONS: VUE reconstructions showed good agreement with TNC attenuation in the liver and spleen in both contrast phases, whereas LVNC systematically underestimated attenuation in iodine-enhancing organs and was closer to TNC than VUE only in subcutaneous fat and venous-phase muscle. Substantial bias in vascular and bone structures limits the interchangeability of both algorithms with TNC imaging. VNC may support a potential reduction in radiation dose when replacing a planned TNC acquisition; since lesion detection and characterization were not evaluated, the safe omission of TNC was not demonstrated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment.Radiology · 2026
- Virtual Noncontrast Imaging with Deep-Silicon Photon-Counting CT: Matched Phantom and Initial Human EvaluationmedRxiv · 2026
- Photon-counting Detector CT Spectral Reconstructions for Radiomics-based Liver Lesion ClassificationInvestigative Radiology · 2026
- Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.Diagnostics (Basel, Switzerland) · 2026
- Feasibility of low concentration iodinated contrast medium in portal venous abdominal imaging: performance of photon-counting CT virtual monoenergetic imaging compared to conventional EID-CT.European journal of radiology · 2026
- Clinical feasibility and image quality assessment of deep learning-based virtual contrast enhancement from photon-counting computed tomography.Journal of clinical imaging science · 2026