Clinical feasibility and image quality assessment of deep learning-based virtual contrast enhancement from photon-counting computed tomography.
Julien G Cohen, Joel Valentin Stadelmann, David Leite-Arada, Pierre-Alexandre Poletti
Division of Radiology, Diagnostic Department, University Hospitals of Geneva, Geneva, Switzerland.
Key points
From the paper's conclusion- The synthesis of VCE images from PCCT datasets is feasible and shows excellent quantitative similarity to TC images, with promising results for thoracic applications but limited reliability for abdominal evaluation at this stage.
Abstract
OBJECTIVES: The purpose of this study was to evaluate image quality and diagnostic performance of deep learning-based virtual contrast-enhanced (VCE) images generated from photon-counting CT (PCCT) datasets. MATERIAL AND METHODS: Forty consecutive patients who underwent contrast-enhanced PCCT were retrospectively included and divided into training (n = 20) and testing (n = 20) cohorts. A supervised U-Net-based convolutional neural network was trained to generate VCE images from virtual non-contrast inputs, using true contrast-enhanced (TC) images as the reference. Quantitative similarity was assessed using the structural similarity index measure (SSIM), mean absolute error (MAE), mean squared error (MSE), and peak signal-to-noise ratio (PSNR). Qualitative evaluation was performed independently by two radiologists using a 5-point Likert scale across thoracic and abdominal structures, with assessment of exact, ±1-point, and diagnostic agreement. RESULTS: Quantitative analysis demonstrated high similarity between VCE and TC images, with very high SSIM and PSNR values and low MAE, while MSE showed a right-skewed distribution. Qualitatively, VCE images were consistently rated lower than TC images. However, central thoracic vascular structures, cardiac chambers, and mediastinal lymph nodes were frequently rated as diagnostic (Likert ≥3) with high diagnostic agreement. In contrast, abdominal solid organs and vessels were often judged non-diagnostic, mainly due to heterogeneous enhancement and apparent contrast defects. CONCLUSION: The synthesis of VCE images from PCCT datasets is feasible and shows excellent quantitative similarity to TC images, with promising results for thoracic applications but limited reliability for abdominal evaluation at this stage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep learning denoising and deep learning-augmented contrast enhancement improve ultra-high-resolution photon-counting-detector CCTA image quality.European radiology experimental · 2026
- Improved virtual non-contrast images in liver dual-energy CT with deep learning algorithm for image reconstruction.Radiologie (Heidelberg, Germany) · 2026
- Image Quality of Non-Contrast Neurological Images on Energy-Integrating versus Silicon Photon-Counting Detector CT.AJNR. American journal of neuroradiology · 2026
- Diagnostic performance of liver virtual non-contrast and virtual unenhanced reconstructions derived from photon-counting detector CT of the upper abdomen.Abdominal radiology (New York) · 2026
- Deep Learning Reconstruction for Ultra-High-Resolution Photon-Counting CT of the Lung: Image Quality and Texture CharacterizationmedRxiv · 2026
- Virtual Noncontrast Imaging with Deep-Silicon Photon-Counting CT: Matched Phantom and Initial Human EvaluationmedRxiv · 2026