Photon-counting Detector CT Spectral Reconstructions for Radiomics-based Liver Lesion Classification
Friedrich L. Pietsch, Abhinay Vellala, Florian Haag, Alexander Hertel, Javier Contreras, Parisa Kaviani, Anushree M. Burade, Dominik Nörenberg,
Key points
From the paper's conclusion- This study aimed to evaluate the performance of radiomics-based machine learning for differentiating benign and malignant liver lesions using multispectral virtual monochromatic and material decomposition images derived from contrast-enhanced PCD-CT.
Abstract
OBJECTIVES: Accurate noninvasive classification of hepatic lesions remains a diagnostic challenge, particularly on conventional CT. Photon Counting Detector CT (PCD-CT) offers spectral imaging capabilities that may enhance tissue characterization. This study aimed to evaluate the performance of radiomics-based machine learning for differentiating benign and malignant liver lesions using multispectral virtual monochromatic and material decomposition images derived from contrast-enhanced PCD-CT. MATERIALS AND METHODS: This multicenter study included patients with focal hepatic lesions, scanned on PCD-CT at 2 separate institutions. Lesions were automatically segmented by a nnU-Net model and confirmed by an abdominal radiologist. Volumetric segmentations were used to extract radiomic features from 9 spectral datasets: 40, 50, 70, 90, 110, 140, and 180 keV, virtual non-contrast (VNC), and iodine density maps (IDM). A patient-based classification analysis was conducted by training multiple machine-learning models, with lesion-level predictions aggregated per patient. A Random Forest model further evaluated classification performancef across all train-test reconstruction combinations. RESULTS: The cohort comprised 378 patients (median age: 62; 59.5% female) from 2 centers, including 190 benign (n=227 lesions) and 188 with malignant (n=2681 lesions) hepatic findings. Random forest model trained on VNC achieved highest performance [AUC: 0.899; 95% CI (0.840-0.951); Accuracy 83.5%). In the cross-domain analysis, all training reconstructions achieved similar mean AUCs (0.75 to 0.83). Evaluation performance varied across test levels. Models tested on 110, 140, and 180 keV, and VNC showed the highest stability (median AUC ≥ 0.83), while 40 keV, 50 keV, and IDM resulted in lower and more variable AUCs (median AUC ≤ 0.71). CONCLUSION: Radiomics-based machine learning enables reliable differentiation between malignant and benign hepatic lesions on PCD-CT. The choice of test reconstruction influenced performance: higher energy levels and VNC images yielded more stable results. Incorporating high-energy reconstructions and VNC images into radiomic workflows for liver lesion risk stratification may enable noninvasive triage and reduce the need for invasive diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Practical applications of photon-counting CT in oncology: an organ-based pictorial review.Insights into imaging · 2026
- Diagnostic performance of liver virtual non-contrast and virtual unenhanced reconstructions derived from photon-counting detector CT of the upper abdomen.Abdominal radiology (New York) · 2026
- Multi-Parametric Spectral Detector CT for the Assessment of Focal Liver Lesions: Evaluation of Readers' Diagnostic Confidence and Economic Effects.Diagnostics (Basel, Switzerland) · 2026
- Noninvasive differentiation of benign and malignant solid pulmonary nodules using multiparameter dual-layer spectral CT radiomics.Insights into imaging · 2026
- Photon-Counting CT With Low-keV Virtual Monoenergetic Images for Detecting Muscle Invasion in Bladder Cancer: A Prospective Study.AJR. American journal of roentgenology · 2026
- Photon-counting detector CT-derived extracellular volume fraction as a complementary biomarker for liver cirrhosis assessment: a retrospective diagnostic accuracy study.Quantitative imaging in medicine and surgery · 2026