Biophysical characterization of a helium beam: In-field and out-of-field microdosimetry and RBE.
Marta Missiaggia, Francesco Giuseppe Cordoni, Giorgio Cartechini, Emanuele Scifoni, Chiara La Tessa
Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida, USA. · Louisiana State University, Baton Rouge, Louisiana, USA.
Key points
From the paper's conclusion- This study provides the first comprehensive experimental microdosimetric characterization of a helium beam at clinically relevant energy across in-field and out-of-field regions. The observed discrepancies with Monte Carlo simulations highlight the need for improved characterization and modeling of secondary-particle production in helium beams. The RBE calculations further illustrate how differences in the physical description and interpretation of heterogeneous radiation fields propagate into biological predictions from different models. Dedicated radiobiological measurements under these irradiation conditions are needed to validate these predictions.
Abstract
BACKGROUND: Helium shows great promise in radiotherapy due to improved dose conformality and higher biological effectiveness compared to protons, but limited data on its physical and biological properties hinder its clinical potential. PURPOSE: This study aims to characterize the microdosimetric distributions of 160 MeV/u helium ions in-field and out-of-field, benchmark the measurements against Monte Carlo simulations, and investigate how the measured radiation quality propagates into radiobiological predictions from mathematical models. METHODS: Microdosimetric measurements were performed using a Tissue Equivalent Proportional Counter (TEPC) in a water phantom at various depths along the beam direction and lateral positions. The experimental data were compared with OpenTOPAS Monte Carlo simulations. The measured microdosimetric spectra and derived microdosimetric quantities were then used as physical input for two microdosimetry-based radiobiological models, the modified Microdosimetric Kinetic Model (mMKM) and the Generalized Stochastic Microdosimetric Model (GSM2), to calculate the Relative Biological Effectiveness (RBE) at each measured location. RESULTS: The microdosimetric characterization revealed increasing radiation quality parameters y ¯ F , y ¯ D and y ∗ along the in-field direction up to the Bragg peak, followed by a decrease in the distal region. The values of y ¯ F range from 2.43 ± 0.19 keV/µm at 50 mm depth to 21.8 ± 1.1 keV/µm at the Bragg peak, and decreasing to 2.39 ± 0.12 keV/µm at 250 mm depth. All microdosimetric parameters declined with depth at the field-edge, while remaining approximately constant close and far out-of-field. OpenTOPAS reproduced the measured spectra with primary helium ions contributing predominantly to the higher-y region and secondary protons to the lower-y region. Although mMKM and GSM2 predicted similar trends, the RBE(0.1) values differed, with the largest variations of up to 37% relative to the mMKM occurring in the distal in-field region. The lack of corresponding in vitro measurements prevents validation of the model predictions and assessment of their accuracy. CONCLUSIONS: This study provides the first comprehensive experimental microdosimetric characterization of a helium beam at clinically relevant energy across in-field and out-of-field regions. The observed discrepancies with Monte Carlo simulations highlight the need for improved characterization and modeling of secondary-particle production in helium beams. The RBE calculations further illustrate how differences in the physical description and interpretation of heterogeneous radiation fields propagate into biological predictions from different models. Dedicated radiobiological measurements under these irradiation conditions are needed to validate these predictions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of experimental and radiobiological model-predicted survival of human laryngeal squamous cell carcinoma cells in a helium spread-out Bragg peak.Physics and imaging in radiation oncology · 2026
- Helium pencil beam commissioning and beam modeling.Physics and imaging in radiation oncology · 2026
- A standardized measurement-based approach to estimate modelled relative biological effectiveness for auditing carbon ion beams.Physics and imaging in radiation oncology · 2026
- A mechanism-guided approach for quantifying the biological effects of tumor hypoxia in particle therapy.International journal of radiation oncology, biology, physics · 2026
- Biological effectiveness of high-energy proton transmission beams: in vitro evaluation of cell survival and viabilityPhysics in Medicine and Biology · 2026
- An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy.Physics in medicine and biology · 2026