Key points
From the paper's conclusion- While modelled RBE has extensive associated uncertainty, this study demonstrated that it could be estimated with reasonable accuracy using a standardized measurement-based framework. Results suggested that microdosimetry can be used as a quality assurance tool to characterize carbon fields and verify correct implementation of RBE models.
Abstract
BACKGROUND AND PURPOSE: Differences in dose delivered during carbon radiotherapy are due largely to variations in relative biological effectiveness (RBE), which can be calculated by several models. While RBE can theoretically be calculated using Microdosimetric Kinetic Model (MKM) and measured microdosimetric quantities, clinical implementation relies on lookup tables. There exist no means of measuring RBE by MKM or other common models, including Repair Misrepair Fixation (RMF) and Local Effect Model-I (LEM). This study investigated estimating RBE using a single microdosimetric measurement for each model, allowing measurement-based validation and inter-model comparison. MATERIALS AND METHODS: Monte Carlo simulations were performed at 260 positions across nine carbon beams, from which microdosimetric quantities ( y ∗ ) and linear ( α ) and quadratic ( β ) RBE parameters were derived using each model definition. To estimate RBE from microdosimetric input, α and β were fit as functions of y ∗ for two test beams. The fits were applied to microdosimetric data from the remaining simulated beams and experimental measurements to validate resulting RBE predictions against full Monte Carlo-calculated RBE. RESULTS: Modelled RBE calculated using simulated input parameters versus estimated with the measurement-based fit were compared and found to be within ±10% accuracy in 96% (MKM), 100% (LEM), and 98% (RMF) of points. Average estimation uncertainty was 2.6% (MKM), 1.7% (LEM), and 4.3% (RMF). CONCLUSIONS: While modelled RBE has extensive associated uncertainty, this study demonstrated that it could be estimated with reasonable accuracy using a standardized measurement-based framework. Results suggested that microdosimetry can be used as a quality assurance tool to characterize carbon fields and verify correct implementation of RBE models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- LETd-dependent RBE conversion between LEM1- and mMKM-based dose systems and characterisation of LETd-dependent uncertainty in carbon ion radiotherapy.Physics in medicine and biology · 2026
- Biologically optimized 3D range modulators for fast conformal carbon ion therapy:in vitrovalidation, treatment planning, and robustness analysis.Physics in medicine and biology · 2026
- Reanalysis of Mechanism-Inspired Relative Biological Effectiveness Models Based on Track-structure Monte Carlo Simulation.International journal of radiation oncology, biology, physics · 2026
- Multi-model RBE and dose-averaged LET optimized carbon ion radiotherapy for sacral chordoma: results of the first year of clinical application.International journal of radiation oncology, biology, physics · 2026
- Type-B uncertainties related to ionization chamber modelling in Monte Carlo based reference dosimetry for clinical proton and carbon ion beams.Physics and imaging in radiation oncology · 2026
- A Clinical Dose Prescription System for Proton Radiotherapy Based on the Mayo Clinic Florida Microdosimetric Kinetic Model.International journal of radiation oncology, biology, physics · 2026