Key points
From the paper's conclusion- In this SQ20B cell model under the present experimental conditions, NanOx predictions differed from experimental data by 20-37% depending on position. These results support further validation of the model in a broader range of cell lines and helium ion irradiation configurations.
Abstract
BACKGROUND AND PURPOSE: Helium ion therapy offers favorable dose distributions and potential biological advantages over photon and proton therapies, yet data on cellular response in clinically relevant Spread-Out Bragg Peak (SOBP) configurations remain limited. This study measured the surviving fraction of radioresistant human laryngeal squamous cell carcinoma (SQ20B) cells irradiated in a helium SOBP and compared experimental results with predictions from NanOx, a nanodosimetry and oxidative stress model implemented in Monte Carlo simulations. MATERIALS AND METHODS: SQ20B cells were irradiated at three positions along a helium SOBP using a passive beamline. Survival fractions were measured for doses between 1 and 4 Gy. The setup was simulated in GATE, and survival was predicted using the NanOx model via the Biodose Actor. Relative biological effectiveness (RBE) was derived from linear quadratic fits using photon reference parameters. RESULTS: NanOx predicted decreasing survival towards the distal edge, with surviving fractions at 4 Gy of 11%, 7%, and 4% at the proximal edge, plateau, and distal edge, respectively. Experimentally, fitted surviving fractions at 4 Gy were 10%, 12%, and 8%, showing no spatial trend. Deviations between model predictions and experimental averages ranged from 20 to 37%. Experimental RBE values ranged from 2.1 to 2.4, in reasonable agreement with NanOx predictions (2.1-2.9). CONCLUSIONS: In this SQ20B cell model under the present experimental conditions, NanOx predictions differed from experimental data by 20-37% depending on position. These results support further validation of the model in a broader range of cell lines and helium ion irradiation configurations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A mechanism-guided approach for quantifying the biological effects of tumor hypoxia in particle therapy.International journal of radiation oncology, biology, physics · 2026
- Biophysical characterization of a helium beam: In-field and out-of-field microdosimetry and RBE.Medical physics · 2026
- An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy.Physics in medicine and biology · 2026
- A cell-type resolved proton RBE model for potential clinical application.Medical physics · 2026
- The risk of radiotherapy toxicity in patients with laryngeal cancer: predictive factors and radiobiological modelling.Oncology research and treatment · 2026
- Helium pencil beam commissioning and beam modeling.Physics and imaging in radiation oncology · 2026