An experimentally calibrated nanodosimetry-based framework for predicting LET-dependent relative biological effectiveness in proton boron capture therapy.
Junxiang Wu, Zhencen He, Zhao Sun, Lang Dong, Tianle Wang, Jiajun Kang, Liyuan Deng, Zhuohang He,
Sichuan University Institute of Nuclear Science and Technology, 24 South Section 1,1st Ring Road, Chengdu, Sichuan, 610065, China. · Sichuan Cancer Hospital and Institute, No.55,Section 4,South Renmin Road,Chengdu,China, Chengdu, Sichuan, 610041, China.
Key points
From the paper's conclusion- An experimentally calibrated framework integrating MC simulation, nanodosimetry, radiobiological experiments, and the LNDM was established for LET-dependent PBCT RBE prediction based on biological calibration data.
Abstract
OBJECTIVE: Proton boron capture therapy (PBCT) studies focus on physical dose enhancement or biological observations, while quantitative prediction of biological effectiveness remains limited. This study aimed to establish a framework combining Monte Carlo (MC) simulation, nanodosimetry, and radiobiological experiments to evaluate the relative biological effectiveness (RBE) of PBCT. APPROACH: Geant4-based MC simulations and a pre-calculated nanodosimetric database were used to determine mixed-field nanodosimetric parameters, including M1, M2, and F2. Clonogenic survival experiments were performed using a clinical 70 MeV proton beam and a 6 MV photon beam. U-87 MG cells were irradiated with photons, protons, and PBCT at 0, 2, 4, 6, and 8 Gy using boronophenylalanine (BPA, 21.0 ppm 11B). Survival data were fitted with the linear-quadratic model, and the resulting α and β values were used to optimize the Logistic Nanodosimetry Model (LNDM) for depth-dependent RBE prediction. MAIN RESULTS: The LNDM, combined with MC-derived nanodosimetric parameters and experimental survival data, reproduced the measured radiobiological response with differences in α and β below 0.5% at the experimental cell position, corresponding to a water-equivalent depth (WED) of 3.9 cm and located on the rising edge of the Bragg peak. PBCT consistently exhibited higher α and RBE values than proton irradiation across the investigated LET range. At 3.9 cm, PBCT increased RBE by 8.7% compared with protons. For the 70 MeV beam, PBCT yielded α = 0.116 Gy⁻¹, β = 0.023 Gy⁻², and RBE = 1.25, compared with α = 0.076 Gy⁻¹, β = 0.023 Gy⁻², and RBE = 1.15 for proton therapy. SIGNIFICANCE: An experimentally calibrated framework integrating MC simulation, nanodosimetry, radiobiological experiments, and the LNDM was established for LET-dependent PBCT RBE prediction based on biological calibration data. PBCT showed consistently higher RBE than proton therapy, with a greater advantage at higher LET, supporting future biological optimization of PBCT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A cell-type resolved proton RBE model for potential clinical application.Medical physics · 2026
- A comprehensive microdosimetric study of neutron capture enhanced proton therapy: physical dose to RBE-based evaluation.Journal of radiation research · 2026
- Microdosimetric characterization of proton relative biological effectiveness in pancreatic ductal adenocarcinoma cell lines.Frontiers in oncology · 2026
- Proton boron capture therapy and neutron capture enhanced proton therapy: a critical review of investigational approaches in proton therapy.Radiological physics and technology · 2026
- Biological effectiveness of high-energy proton transmission beams: in vitro evaluation of cell survival and viabilityPhysics in Medicine and Biology · 2026
- Comparison of experimental and radiobiological model-predicted survival of human laryngeal squamous cell carcinoma cells in a helium spread-out Bragg peak.Physics and imaging in radiation oncology · 2026