Deteriorated Hysteresis Behavior of Reinforced Concrete Bridge Columns With Lap‐Spliced Circular Hoop Reinforcement
Ping‐Hsiung Wang, Cheng‐Yu Huang, Chiao‐Chu Tseng
Key points
From the paper's conclusion- Five lap‐spliced circular hoop (CH) concrete bridge columns, designed in accordance with the current Japanese bridge design code and Taiwan bridge design practice, were tested in this study to investigate the effects of longitudinal reinforcement and aspect ratios on deteriorated hysteresis behavior.
Abstract
Five lap‐spliced circular hoop (CH) concrete bridge columns, designed in accordance with the current Japanese bridge design code and Taiwan bridge design practice, were tested in this study to investigate the effects of longitudinal reinforcement and aspect ratios on deteriorated hysteresis behavior. Another five circular spiral (CS) bridge column test results from the literature were also included to further discuss the effects of the confining mechanism. The 90‐degree hooks of the lap‐spliced hoops would lose their anchorage once the core concrete had crushed, after which the supplementary crosstie became essential to prevent the confining mechanism from disintegrating. The test results indicate that the ultimate drift capacity of the CH columns, defined by 20% strength deterioration on the envelope curves, increased slightly and moderately with increasing longitudinal reinforcement ratio and aspect ratio, respectively. The identified deterioration parameters indicate that the stiffness degradation and pinching severity of the CH and CS columns increased as the longitudinal reinforcement ratio decreased. In contrast, the aspect ratio had a limited effect on stiffness degradation. However, as the aspect ratio decreased, the CS and CH columns exhibited less pinched and more pinched reloading behavior, respectively. The identified strength deterioration parameters indicate that column CH307 (or CS407), which had a low longitudinal reinforcement ratio, was vulnerable to cyclic excursions and would reach its ultimate state (i.e., damage index = 1.0) at a lower displacement capacity than its two counterparts with a higher longitudinal reinforcement ratio under the same loading history.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Behavior of FRP‐Reinforced Concrete Columns Subjected to Combined Axial Compression and Lateral LoadingAdvances in Civil Engineering · 2026
- Assessment and design of restrained reinforced concrete beams subjected to hysteresis elongation effectsEngineering Structures · 2025
- Cyclic tensile behavior and component‐based modeling of box connections in prefabricated concrete elevator shafts for retrofitting old dwellingsStructural Concrete · 2026
- Axial Compressive Behaviour of Intermediate-Length Concrete-Filled Steel Tubular Columns with Different CFRP Wrapping ConfigurationsBuildings · 2026
- Nonlinear Finite Element Investigation of Steel–Concrete Interface Effects on the Cyclic Behavior of Steel-Reinforced Concrete (SRC) ColumnsBuildings · 2026
- Investigating the Performance of Rehabilitated Non-Prismatic Reinforced Concrete Columns Subjected to Cyclic LoadCivil and Environmental Engineering · 2026