  • Five lap‐spliced circular hoop (CH) concrete bridge columns, designed in accordance with the current Japanese bridge design code and Taiwan bridge design practice, were tested in this study to investigate the effects of longitudinal reinforcement and aspect ratios on deteriorated hysteresis behavior.

Abstract

Five lap‐spliced circular hoop (CH) concrete bridge columns, designed in accordance with the current Japanese bridge design code and Taiwan bridge design practice, were tested in this study to investigate the effects of longitudinal reinforcement and aspect ratios on deteriorated hysteresis behavior. Another five circular spiral (CS) bridge column test results from the literature were also included to further discuss the effects of the confining mechanism. The 90‐degree hooks of the lap‐spliced hoops would lose their anchorage once the core concrete had crushed, after which the supplementary crosstie became essential to prevent the confining mechanism from disintegrating. The test results indicate that the ultimate drift capacity of the CH columns, defined by 20% strength deterioration on the envelope curves, increased slightly and moderately with increasing longitudinal reinforcement ratio and aspect ratio, respectively. The identified deterioration parameters indicate that the stiffness degradation and pinching severity of the CH and CS columns increased as the longitudinal reinforcement ratio decreased. In contrast, the aspect ratio had a limited effect on stiffness degradation. However, as the aspect ratio decreased, the CS and CH columns exhibited less pinched and more pinched reloading behavior, respectively. The identified strength deterioration parameters indicate that column CH307 (or CS407), which had a low longitudinal reinforcement ratio, was vulnerable to cyclic excursions and would reach its ultimate state (i.e., damage index = 1.0) at a lower displacement capacity than its two counterparts with a higher longitudinal reinforcement ratio under the same loading history.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Deteriorated Hysteresis Behavior of Reinforced Concrete Bridge Columns With Lap‐Spliced Circular Hoop Reinforcement — Science Skim