Nonlinear Finite Element Investigation of Steel–Concrete Interface Effects on the Cyclic Behavior of Steel-Reinforced Concrete (SRC) Columns
Halit Erdem Çolakoğlu
Key points
From the paper's conclusion- The findings demonstrate that realistic steel–concrete interface modeling is essential for reliable nonlinear finite element simulations and provides practical guidance for the seismic assessment and design of SRC columns.
Abstract
The cyclic response of Steel-Reinforced Concrete (SRC) columns is governed by the interaction between the embedded structural steel section and the surrounding concrete. However, most nonlinear finite element studies assume a perfect bond at the steel–concrete interface, neglecting interface slip that may considerably influence the structural response. This study investigates the effects of steel–concrete interface conditions on the cyclic behavior of SRC columns through three-dimensional nonlinear finite element analyses conducted in ABAQUS. The developed modeling approach was first validated against experimental results available in the literature and demonstrated excellent agreement with the measured global response. A comprehensive parametric investigation was subsequently performed by considering two interface conditions (perfect bond and frictional contact), three axial load ratios, four interface friction coefficients, and different structural steel ratios under displacement-controlled cyclic loading. Structural performance was evaluated in terms of hysteretic response, lateral load capacity, stiffness degradation, and cumulative energy dissipation. The results indicate that the perfect bond assumption consistently overestimates the seismic performance of SRC columns by predicting higher lateral strength, greater stiffness, and significantly larger energy dissipation than the frictional interface model. Depending on the axial load ratio, the cumulative energy dissipation capacity of the frictional model was 44.2–73.1% lower than that of the perfect bond model, while the influence of interface modeling became increasingly pronounced at higher axial load levels. Increasing the interface friction coefficient enhanced the composite action between steel and concrete, although its influence on peak lateral resistance remained relatively limited. The findings demonstrate that realistic steel–concrete interface modeling is essential for reliable nonlinear finite element simulations and provides practical guidance for the seismic assessment and design of SRC columns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Compressive Strength and Stiffness of Steel-Reinforced Concrete Stub Columns Under Axial CompressionBuildings · 2026
- Experimental study on bond behavior between inner steel member and concrete in steel reinforced concrete-filled steel tubesConstruction and Building Materials · 2026
- Experimental and numerical study of RC beam joints to steel-encased RC columns with a transitional partScientific Reports · 2026
- Seismic performance of externally stiffened ring connections between concrete-filled steel tubular columns and reinforced concrete beamsScientific Reports · 2026
- Numerical Analysis of a Novel Integral Composite Frame Beam with End-Plate ConnectionBuildings · 2026
- Experimental and numerical analysis of square tubed steel-reinforced concrete columns: Confinement mechanism and modelingEngineering Structures · 2025